19
Version 010415
- Remove all protective foils and packaging material prior to use.
- Place the appliance on a flat, solid, and heat-resistant surface, on its vertical position.
Never install your appliance on inflammable surface.
- Do not install the appliance near open fireplaces or all hot or explosive sources.
- Clean carefully the ap
pliance and accessories. Don’t use abrasive products. Take care the
control panel must not be in contact with water or humidity
- Connect the appliance directly to a wall plug socket. The use of adaptors, multiple
sockets and/or extensions is not recommended.
- To properly service the appliance and to secure it 10 cm of clearance is needed on all
sides from inflammable materials.
The security distances for inflammable material in relation with their degree of
flammability
A no inflammable granite, sandstone, concreted brick, ceramic tiling, coat of plaster,
B Uneasy to inflame Acumin, heraclite, lihnos, itaver
C1 Bad to inflame wood of hardwood,laminated, reinforced paper, unmakart
C2 Middle flammability agglomerate, solodurn cork-coat,rubber, coating
C3 Easy flammability board made of grain of wood, polystyrene, polyurethane
- Be careful the appliance will not be exposed to warm air directly. Check the distance at
the back, they must be respected to allow extraction of air.
- Your appliance must be installed in a clean environment (dust is not good)
-
The wall back to the appliance must be able to accept a temperature of 60°C. If it’s not
the case a special protection must be installed.
- Be careful that all air extracts issue are free and not obstructed
- Check that the appliance is installed in order it can be used easily enough place for the
user
- Connect the appliance to the water supply (rubber pipe 20/27 supplied with two joints)
- Connect the draining tube to the draining off point. Your draining off point must be lower
that the lower part of the tank of the appliance. To avoid bad smelling provide for installing
a siphon. The draining tube must have an internal diameter of 30mm and a down grade of
3cm per meter.
- Electric connexion: installation of this unit should be performed only by a qualified
service technician and in accordance with the actual text regarding accident prevention.
All wiring connections for this appliance must be made in accordance with the wiring
diagrams furnished on the appliance. To avoid electrical shock, this appliance must be
adequately and safely grounded (earthed) and protected at least 16 amp. If the appliance
is wired directly into the electrical power supply a mean for disconnection from the supply
giving a contact separation of at least 3mm in all poles must be incorporated in the fixed
wiring. This appliance must be positioned so that the plug is accessible unless other
means for disconnection from the power supply are provided.
IMPORTANT
The appliance is operational in an environment with air temperature from +1°C to +45°C
and water temperature from +1°C and 35°C.