![CAS EXI-200AD Manual Download Page 61](http://html1.mh-extra.com/html/cas/exi-200ad/exi-200ad_manual_2565960061.webp)
`
62
9.3 Communication Setting
Menu-F2.01: Equipment Number
Function
Equipment Number
Display Part
Meaning
Set Range
(0 ~ 99)
2-01. XX
Initial Value : 0
Desired device ID may be entered.
Reference 1. This function can be used as the indicator unique ID when using COMMAND mode.
Menu-F2.02: Data Transfer Speed Setting
Function
Data Transfer Speed Setting
Display Part
Meaning
Set Range
(0 ~ 9999)
XXXX
Initial Value :
50x10ms
Data are transmitted by the unit of 00 x 10ms
Reference 1. When set to “0”, data is transferred in real-time.
Menu-F2.03: Set COM1 Port
Function
Com1 RS-232C Port Setting
Display Part
Meaning
2-03. 0
Data Bit 8, Stop Bit 1, Parity Bit : None
2-03. 1
Data Bit 7, Stop Bit 1, Parity Bit: Even
2-03. 2
Data Bit 7, Stop Bit 1, Parity Bit: Odd
2-03. 3
Data Bit 7, Stop Bit 2, Parity Bit: Odd
2-03. 4
Data Bit 8, Stop Bit 1, Parity Bit: Even
Set Range
( 0~ 5)
2-03. 5
Data Bit 8, Stop Bit 1, Parity Bit: Odd
Menu-F2.04: Set COM1 Baud Rate
Function
COM1 RS-232C Baud Rate Setting
Display Part
Meaning
2-04. 0
1,200 bps
2-04. 1
2,400 bps
2-04. 2
4,800 bps
2-04. 3
9,600 bps
2-04. 4
19,200 bps
2-04. 5
38,400 bps
2-04. 6
57,600 bps
Set Range
(0 ~ 7)
2-04. 7
115,200 bps
Menu-F2.05: Set COM1 Out Data
Function
COM1 RS-232C Out Data Setting
Display Part
Meaning
2-05. 0
Displayed value is transmitted
2-05. 1
Gross Weight is transmitted
Set Range
(0 ~ 2)
2-05. 2
Net weight is transmitted
Summary of Contents for EXI-200AD
Page 1: ... 2 이미지 추가 ...
Page 20: ...21 4 External Explanation 4 1 External Specifications ...
Page 28: ...29 2 DCType ...
Page 29: ... 30 5 1 2 Load Cell Connector ...
Page 31: ... 32 5 1 3 RS 232 RS 485 Connector RS 485 RS 232 COM2 RS 232 COM1 ...
Page 98: ...99 MEMO ...
Page 99: ... 100 MEMO ...
Page 100: ...101 ...