Pin
Explanation
Connection Note
Tx
PC D-SUB No.2
RS-232
Rx
PC D-SUB No.3
RS-232
GND
PC D-SUB No.5
RS-232
IN+
485 Converter T+
RS-485/422
IN-
485 Converter T-
RS-485/422
OUT+
485 Converter R+
RS-485/422
OUT-
485 Converter R-
RS-485/422
Reference 1. For the computer RS-422 and RS-485 line PIN numbers, please refer to the PCI
card or converter (RS-422) manual.
Reference 2. The RS-422 method transfers signals by voltage difference and is more stable in
terms of electric noise compared to other methods.
Shield Cable. In addition the wiring should be separated from the AC power
cable or electric wiring and for cables communication-specific shield cables (0.5
Φ
or greater) should be used. The recommended use distance is within 1.2km.