![CAS EXI-200AD Manual Download Page 57](http://html1.mh-extra.com/html/cas/exi-200ad/exi-200ad_manual_2565960057.webp)
`
58
Menu-F1.08: Set Weight Back-up
Function
Weight Back-up Setting
Display Part
Meaning
1-08. 0
Weight back up function is not used
Set Range
(0, 1)
1-08. 1
Weight back up is used (based on operation)
Menu-F1.09: Set Zero Key Range
Function
Zero Key Range Setting
Display Part
Meaning
Set Range
(0~99)
1-09. XX
Initial Value :
10 %
Zero operates up to /-
ᄋᄋ
% of the maximum weight
Menu-F1.10: Set Tare Key Range
Function
Tare Key Range Setting
Display Part
Meaning
Set Range
(0~100)
1-10. XX
Initial Value :
100 %
Tare operates up to /-
ᄋᄋ
% of the maximum weight
Menu-F1.11: Set Initial Zero Range
Function
Initial Zero Range Setting
Display Part
Meaning
Set Range
(0~99)
1-11. XX
Initial Value :
10%
Initial zero operates /-
ᄋᄋ
% of the Gross Weight
Menu-F1.12: Set Overload Range
Function
Overload Range Setting
Display Part
Meaning
Set Range
(0~99)
1-12. XX
Initial Value :
9 x 1 Digit
Overweight from the next to 0 x 1 Digit of the maximum weight