2.1.1.
C4 Setting
2.1.1.1.
C4-1 Setting
BIT 6~7
Initial Zero range
3
5%
2
10%
1
3%
0
2%
BIT5
Tare Type
0
Proper tare
1
Full Tare
BIT4
BIT 2~3
Successive tare
3
(+), (-) Direction successive Tare
2
(-) Direction successive Tare
1
(+) Direction successive Tare
0
One Time tare
BIT1
BIT0
2.1.1.2.
C4-2 Setting
BIT7
BIT6
Use PLU Tare
1
Use
BIT5
Use PLU Name
0
Don't use
1
Use
BIT4
Use Daily Total
0
Don't use
1
Use
BIT3
Clear Price
0
Don't clear
1
Clear
BIT2
Clear Tare
0
Don't clear
1
Clear
BIT1
Use Euro
0
Don't use
1
Use
BIT0
Power On Euro
0
No
1
Yes
2.1.1.3.
C4-3 Setting
BIT7
Dot Type
0
"." dot
1
"," comma
BIT6
Use Preset tare
0
Don't use