13
7/4/2007
4
O.OOOO
3
O.OOO
2
O.OO
1
O.O
0
O
BIT3
Use Unit message
0
Don't use
1
Use
BIT2
Use Total price window over
0
Don't use
1
Use
BIT 0~1
Print type
3
Don't use
2
DEP-50
1
0
2.1.2.
SPAN Calibration Setting (C-3)
(1)
Pressing and holding “Calibration Switch” press [POWER] key.
After “CAL” message blinks three times and shows the version of scale, it displays “CAL 1”
message.
(2)
Press [ZERO] to display “CAL-3”.
(3)
Press [TARE] key and then it displays “zero ” message.
(4)
Press [TARE] key and then it displays “midup” message
(5)
Load middle weight (ex:1/3 full capacity) on the platform
(6)
Press [TARE] key and then it displays “span ” message
(7)
Load full weight on the platform
(8)
Press [TARE] key and then it displays “middn” message
(9)
Load middle weight (ex:1/3 full capacity) on the platform
(10)
Press [TARE] key and then it display “CAL 3” message
2.1.3.
Gravity Constant Value Setting (C-9)
Current gravitational Acceleration value is set to 9.7994 m/s
2
.
(1)
Pressing and holding “Calibration Switch” press [POWER] key.
After “CAL” message blinks three times and shows the version of scale, it displays “CAL-1”
message.
(2)
Press [ZERO] to display “C-9”.