![CAS CI-100A Operation & Service Manual Download Page 32](http://html1.mh-extra.com/html/cas/ci-100a/ci-100a_operation-and-service-manual_2565919032.webp)
CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA
Corporation
www.cas-usa.com
30
10.5 After
Low
being shown, last setting of low will be displayed, use
,
ACC
,
UNIT
key to input new
number of low and press
TARE
key to confirm. Annunciator of
Lo
will be shown in this step. Press
ZERO
key to exit and back to original working mode.
NOTE: If High number is 0 or is equal or less than low number, the comparison will be disabled.
10.6 After a reasonable limitation is set and compare function is be active, one of announciators
HI, OK, LO
will be lighted, and the beeper will sound according to its setting in
USER-BEEP
.
10.7 For details, please refer to section of section5.13, 6.6 and 7.6
11. Accumulation
11.1 Accumulation function can be used in normal weighing mode, counting mode and percent weighing mode,
When this function is enabled, you can accumulate current net weight, piece, and percentage. Note, only
the load on scale is larger than
USER-OTHER-NLD.RNG
, the displayed positive number can be added
up. The accumulation times and total can be displayed or printed.
11.2 To make data accumulation function be available,
CONFIG-FUNC-ACCUMU
menu item should set to
MANUAL
or
AUTO
, Following are details.
11.3 When
CONFIG-FUNC-ACCUMU
is set to
MANUAL
, the stable and positive displayed net weight (must
be larger than
USER-OTHER-NLD.RNG)
, piece or percentage can be accumulated by long pressing
TOTAL
key, and indicator will display accumulation times first, and then display total of number. To avoid
repeating accumulation for same load, one load only can be accumulated once. So, before a new load put
onto the scale, the original load should be removed and let load on scale be smaller than
USER-OTHER-NLD.RNG
.
11.4 When
CONFIG-FUNC-ACCUMU
is set to
AUTO
, the stable and positive displayed net weight (must be
larger than
USER-OTHER-NLD.RNG)
, piece or percentage can be accumulated automatically, and
indicator will display accumulation times first, and then display total of number. To avoid repeating
accumulation for same load, one load only can be accumulated once. So, before a new load put onto the
scale, the original load should be removed and let load on scale be smaller than
USER-OTHER-NLD.RNG
.
11.5 To view total, when display number is zero, long pressing
TOTAL
key, and indicator will display
accumulation times first, and then display total of number. It will alternative display accumulation times
and weight (or quantity, or percentages) until the
TOTAL
key being pressed again.
NOTE
:
When HOLD function is enable, and scale is working in PEAK HOLD mode ( CONFIG-HOLD=YES,
USER-HOLD-HLD.MOD=PS.PEAK/NG.PEAK), Accumulation function will be automatically
disabled!!!