CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA
Corporation
www.cas-usa.com
25
TARE
key to enter input piece weight mode.
6.5.1.1 When
UNIT.KG
is shown, use
or
ACC
key to select the unit of piece weight, use
TARE
key to
confirm and go to next. Press
ZERO
key to exit getting piece weight mode and back to counting
mode.
6.5.1. When last stored piece weight is shown, use
,
ACC
,
UNIT
key to input new piece weight,
press
SETUP
key more than 3s to input decimal point. Press
TARE
key to confirm and save it, then
go back to counting mode. If the input piece weight is less than 0.5d, the indicator will display
PWt.Er
and go back to counting mode.
6.5.2
Obtain piece weight by weighing samples weight which quantity: in counting mode, press
UNIT
key,
When
InP.PWt
is shown, use
or
ACC
key to select
SPL.PWT,
press
TARE
key to weigh
samples (which quantity is known) weight, calculate piece weight. Press
ZERO
key to exit getting
piece weight mode and back to counting mode.
6.5.2.1 When
SPL.Lo
is shown, move away any sample on scale and press
TARE
key to confirm, before
scale is stable,
SPL.Lo
will be flashed. After it is stable, it will go to next step. Press
ZERO
key to
exit getting piece weight mode and back to counting mode.
6.5.2.2 When
SPL.Hi
is shown, put samples (its quantity is known) onto the scale, Press
TARE
key to
confirm reading weight. Before scale is stable,
SPL.Hi
will be flashed. After it is stable, it will go to
next step. Press
ZERO
key to exit getting piece weight mode and back to counting mode.
6.5.2.3 After
INP.PCS
being shown, 000000 will be displayed, use
,
ACC
,
UNIT
key to input the
quantity of samples and Press
TARE
key to confirm. If the calculated piece weight is less than 0.5d,
the indicator will display
PWt.Er
and go back to counting mode, otherwise, after the reasonable
piece weight being got, the scale will go back to counting mode. The got piece weight can be saved
after the power off and can be used next time.
6.6
Check Counts (counts compare)
in Counting mode:
6.6.1
To make counts compare function be available,
CONFIG-FUNC-COMPAR
item should set to
YES
,
and high and low limitation of pieces should be set correctly according to following steps:
6.6.2
In counting working mode, Press down
DATA
key more than 3s to input compare data of high and
low.
6.6.3 After
HIGH
being shown, 000000 will be displayed, use
,
ACC
,
UNIT
key to input high
quantity number and press
TARE
key to confirm. Annunciator of
Hi
will be shown in this step. Press
ZERO
key to exit getting piece weight mode and back to counting mode.
6.6.4 After
Low
being shown, 000000 will be displayed, use
,
ACC
,
UNIT
key to input low quantity
number and press
TARE
key to confirm. Annunciator of
Lo
will be shown in this step. Press
ZERO
key to exit getting piece weight mode and back to counting mode.
NOTE:
If High number is 0 or is equal or less than low number, the comparison will be disabled.
6.6.5
After a reasonable limitation is set and compare is be active, one of annunciator
HI, OK, LO
will be
lighted, and the beeper will sound according to its setting in
USER-BEEP.