background image

timer will start counting down 15, 14, 13...0 minutes. Once the
timer expires the control will allow a new mode to restart the
equipment. The internal time, as well as the cooling 5-minute
timeguard can be cleared by using the comprotec override feature.

CARE AND MAINTENANCE

For continuing optimum performance and to minimize possible
equipment failure, it is essential that periodic maintenance be
performed on this equipment. Consult your servicing contractor for
the proper frequency of maintenance. Frequency may vary depend-
ing upon geographic areas.

Fig. 14—Electronic Programmable Thermostat Wiring Diagrams

A97295

W

/

W1

Y1

/

W2

G

R

Y

/

Y2

COOL STAGE 1

PROGRAMMABLE

ELECTRONIC

THERMOSTAT

MODEL 2S

TWO-ZONE BOARD
THERMOSTAT
INPUT

FAN

HEAT STAGE 1

COOL STAGE 2

HEAT STAGE 2

24 VAC HOT

24 VAC COMM

N/A

TROUBLE

OUTDOOR
SENSOR
CONNECTION

TWO-STAGE HEAT,
TWO-STAGE COOL

SEE NOTES 1, 2, AND 3

O

/

W2

B

C

G

Y1

W1

Y2

R

C

L

S1

S2

W2

*

W

/

W1

G

Y

/

Y2

O

/

W2

Y1

/

W2

R

24 VAC HOT

TWO-ZONE BOARD
THERMOSTAT
INPUT

FAN

HEAT STAGE 1

COOL STAGE 1

HEAT STAGE 2

N/A

24 VAC COMM

N/A

N/A

OUTDOOR
SENSOR
CONNECTION

TWO-STAGE HEAT,
SINGLE-STAGE COOL

SEE NOTES 1, 2, AND 3

B

C

G

R

W1

Y1

W2

Y2

C

L

S1

S2

*

W

/

W1

G

Y

/

Y2

O

/

W2

Y1

/

W2

R

24 VAC HOT

PROGRAMMABLE

ELECTRONIC

THERMOSTAT

MODEL AC

PROGRAMMABLE

ELECTRONIC

THERMOSTAT

MODEL HP

TWO-ZONE BOARD
THERMOSTAT
INPUT

FAN

HEAT STAGE 1

COOL STAGE 1

N/A

N/A

24 VAC COMM

N/A

N/A

OUTDOOR
SENSOR
CONNECTION

SINGLE-STAGE HEAT,
SINGLE-STAGE COOL

SEE NOTES 1 AND 3

B

C

G

R

W1

Y1

W2

Y2

C

L

S1

S2

*

WIRING DIAGRAM NOTES:

* Hook up G on zone 1 thermostat only.
Set thermostat dip switch A to ON. 
Set thermostat dip switch C to ON.  This will disable 
timeguard and cycle protection in thermostat by setting
it to ZONE mode.  Refer to thermostat Installation Instructions 
for details on how to do this.

1.
2.
3.

8

Summary of Contents for WeatherMaker Two-Zone

Page 1: ...F and 150 F 2 Use vibration isolators flex connectors on zone dampers and ductwork to minimize noise 3 Place dampers away from areas that may be noise sensitive 4 TXV is required in air conditioning...

Page 2: ...mark on the end of the damper shaft represents the position of the damper blade NOTE Insulate damper using 1 1 2 in insulation check local codes In areas where excessive condensing may occur carefully...

Page 3: ...NOTE All zone dampers and ductwork must be properly sup ported according to local codes or SMACNA standards RECTANGULAR FIBROUS GLASS DUCTWORK 1 Insert 1 end of zone damper into 1 end of fibrous glas...

Page 4: ...e thermostat demand warrants Turn off heating or cooling equipment when all zones are satisfied Open all zone dampers when equipment is turned off after 90 sec delay This is the basic sequence of oper...

Page 5: ...ortant that this tempera ture is properly set For gas or oil furnaces the temperature limit will be in the higher temperature range For heat pumps the temperature setting should always be in the lower...

Page 6: ...4 F A E C K J I H L M N 2 3 1 ZONE 1 I O CENTER CONNECTIONS G G Y2 Y2 Y1 Y1 R R W1 W1 W2 W2 C C THERMOSTAT SUBBASE CONNECTIONS ONLY HOOKUP C WHEN SUPPLIED BY THERMOSTAT HOOKUP WHEN USING APPLICABLE TW...

Page 7: ...C Y Y2 R 24 VAC HOT TWO ZONE BOARD THERMOSTAT INPUT 24 VAC COMM HEAT STAGE 1 COOL STAGE 2 FAN HEAT STAGE 2 COOL STAGE 1 N A TROUBLE OUTDOOR SENSOR CONNECTION TWO STAGE HEAT TWO STAGE COOL SEE NOTES 1...

Page 8: ...A TROUBLE OUTDOOR SENSOR CONNECTION TWO STAGE HEAT TWO STAGE COOL SEE NOTES 1 2 AND 3 O W2 B C G Y1 W1 Y2 R C L S1 S2 W2 W W1 G Y Y2 O W2 Y1 W2 R 24 VAC HOT TWO ZONE BOARD THERMOSTAT INPUT FAN HEAT ST...

Page 9: ...proper air temperatures DTO A Damper Fuse Protects damper from electrical dam age 3 Amp B High Heating Temperature Trip Limit Setting When DTO is On temperature is sensed by duct temperature sensor Wh...

Page 10: ...2 times and Red flashes 1 time HP temperature sensor error Second stage heat limit exceeded Wait until HP temperature cools below ex ceeded temperature trip Fixed at 105 F Green flashes 2 times and R...

Page 11: ...391 124 3469 1 288 167 1480 0 645 39 26 686 3 637 82 8776 2 337 126 3340 1 252 169 1431 0 626 41 25 396 3 587 84 8407 2 284 127 3217 1 217 171 1385 0 608 43 24 171 3 537 86 8056 2 231 129 3099 1 183 1...

Page 12: ...Y C W R G Y C RH G W2 W1 Y1 Y2 O B RC TWO ZONE SYSTEM Fig 18 FK4C Fan Coil With Single Speed Air Conditioner A97299 SINGLE SPEED AIR CONDITIONER FK4C FAN COIL C Y G W2 Y Y2 C R Y1 O RH G W2 W1 Y1 Y2...

Page 13: ...RH G W2 W1 Y1 Y2 O B RC TWO ZONE SYSTEM See note 2 Fig 22 FK4C Fan Coil With 2 Speed Air Conditioner A97303 RH G W2 W1 Y1 Y2 O B RC 2 SPEED AIR CONDITIONER FK4C FAN COIL TWO ZONE SYSTEM R G R C W1 W2...

Page 14: ...T C Y 2 1 3 OUTDOOR THERMOSTAT KHAOT0301FST See notes 4 5 6 and 7 KHAIC0101AAA Fig 24 Two Stage or Variable Speed Furnace With Single Speed Heat Pump A97305 2 STAGE OR VARIABLE SPEED FURNACE TWO ZONE...

Page 15: ...W3 C R Y Y2 O L E Y1 C W2 Y O RH G W2 W1 Y1 Y2 O B RC See notes 1 and 3 Fig 28 Two Stage or Variable Speed Furnace With 2 Speed Heat Pump A97309 2 SPEED HEAT PUMP 2 STAGE OR VARIABLE SPEED FURNACE C...

Page 16: ...rmostat AUTO CHANGEOVER mode with dual fuel applications keep both thermostats in same mode heating or cooling 7 Configure Two Zone Control board jumpers for J1 T stat Fnc J3 Equipmt HP J4 Fnc Ht w fa...

Reviews: