9
1
BEFORE OPERATION
Remote Control Configuration
• Dew drop type remote is used for heat pump type air conditioner and cool
only type air conditioner.
Before user operates air conditioner, thus, cool only type and heat pump
type of remote configuration and other items must be selected as follows.
Press the
and
buttons of the infrared remote controller
and hold them pressed for more than 5 seconds.
The display will be cleared, the temperature segments will
display the first configuration item (CH = remote address) and
the time segments will display the default value of this
configuration item (A = control of both indoor units).
Press either the
or
button to change the default value
(A) to the new value (b).
Press
button repeatedly until “tU” is displayed.
Press either the
or
button to change the default value of
temperatures in Degrees Celsius (C) to the new value
Degrees Fahrenheit (
o
F).
Press
button repeatedly until “rc” is displayed.
Press either the
or
button to change the default value of
Heat pump in model type (HP) to new value cooling only
Export (CO1) or cooling only korean (CO2).
Press
button repeatedly until “CL” is displayed.
Press either the
or
button to change the default value of
time format as AM/PM (12) to the new value of 24 hours time
format (24).
LOOK OUT! Whichever configuration value changed must
be confirmed pressing
button each time.
Press
button to leave the configuration menu.
Note:
When 30 seconds have elapsed and no buttons have been
pressed, the remote controller will automatically exit the
configuration menu and the procedure has to be restarted.
9
2
3
4
5
6
7
8
10
11
Confirguration item
Value
Description
"CH"
A : Channel A
Remote ID selection
b : Channel B
Defaults to A
"tU"
C : Degrees C
Temperature units
F : Degrees F
Defaults to C
"rc"
HP : Normal Operation
Puts the Remote into
CO 1 : Cooling Only for Export
Cooling Only Mode
CO 2 : Cooling Only for Korea
Defaults to HP
"CL"
12 : 12 Hour Standard
Time Format
(AM/PM)
Defaults to 12
24 : 24 Hour Military
42KH5A54020_O
2004.6.11, 3:6 PM
Page 9