4
Fig. 1 — AquaSnap
®
Chiller Model Number Designation
LEGEND
*Refer to Table 1 on page 2 for modular unit combinations.
†Sponsored by ASHRAE (American Society of Heating, Refrigerating and Air-
Conditioning Engineers).
NOTE: A “Z” in position 11 indicates a special order machine. Digits following
do not correspond to tables.
CRN
—
Canadian Registration Number
EMM
—
Energy Management Module
GFI-CO
—
Ground Fault Interrupting Convenience Outlet
LON
—
Local Operating Network
SCCR
—
Short Circuit Current Rating
VFD
—
Variable Frequency Device
XL
—
Across-the-Line Start
a30-5694
3
0RB
– Air-Cooled A
quaS
n
a
p® Chiller
De
s
i
g
n
S
erie
s
Nominal
S
ize
s
060 110
170
275
3
60
*
070 120
190
3
00
3
90
*
0
8
0 1
3
0 210
3
15
*
090 150
225
33
0
*
100 160 250
3
45
*
Volta
g
e
1
– 575-
3
-60
2
–
38
0-
3
-60
Conden
s
er Coil Option
s
-
–
Al
u
min
u
m Fin/Copper T
ub
e
0
– Copper Fin/Copper T
ub
e
1
– Al
u
min
u
m Pre-Co
a
t Fin/Copper T
ub
e
2
– Al
u
min
u
m E-Co
a
t Fin/Copper T
ub
e
3
– Copper E-Co
a
t Fin/Copper T
ub
e
4
– Microch
a
nnel (MCHX)
5
– E-Co
a
t, Microch
a
nnel (MCHX)
Cooler Option
s
-
– Integr
a
l Cooler, CRN (C
a
n
a
d
a
)
0
– Integr
a
l Cooler, Cooler He
a
ter, CRN (C
a
n
a
d
a
)
4
– Integr
a
l Cooler, Microch
a
nnel (MCHX), CRN (C
a
n
a
d
a
)
5
– Integr
a
l Cooler, Cooler He
a
ter, Microch
a
nnel (MCHX), CRN (C
a
n
a
d
a
)
G
– Integr
a
l Cooler, no CRN
H
– Integr
a
l Cooler, Cooler He
a
ter, no CRN
K
– Integr
a
l Cooler, Microch
a
nnel (MCHX), no CRN
L
– Integr
a
l Cooler, Cooler He
a
ter, Microch
a
nnel (MCHX), no CRN
R
– Integr
a
l Cooler, Microch
a
nnel (MCHX), He
a
t Recovery, no CRN
S
– Integr
a
l Cooler, Cooler He
a
ter, Microch
a
nnel (MCHX), He
a
t Recovery,
no CRN
T
– Integr
a
l Cooler, Microch
a
nnel (MCHX), He
a
t Recovery, CRN (C
a
n
a
d
a
)
V
– Integr
a
l Cooler, Cooler He
a
ter, Microch
a
nnel (MCHX), He
a
t Recovery,
CRN (C
a
n
a
d
a
)
Hydronic
s
Option†
-
– No P
u
mp In
s
t
a
lled
0
–
S
ingle P
u
mp,
3
HP
1
–
S
ingle P
u
mp, 5 HP
2
–
S
ingle P
u
mp, 7.5 HP
3
–
S
ingle P
u
mp, 10 HP
4
–
S
ingle P
u
mp, 15 HP
6
– D
ua
l P
u
mp,
3
HP
7
– D
ua
l P
u
mp, 5 HP
8
– D
ua
l P
u
mp, 7.5 HP, Low He
a
d
9
– D
ua
l P
u
mp, 7.5 HP, High He
a
d
B
– D
ua
l P
u
mp, 10 HP
C
– D
ua
l P
u
mp, 15 HP
F
–
S
ingle P
u
mp,
3
HP with VFD
G
–
S
ingle P
u
mp, 5 HP with VFD
H
–
S
ingle P
u
mp, 7.5 HP with VFD
J
–
S
ingle P
u
mp, 10 HP with VFD
K
–
S
ingle P
u
mp, 15 HP with VFD
M
– D
ua
l P
u
mp,
3
HP with VFD
N
– D
ua
l P
u
mp, 5 HP with VFD
P
– D
ua
l P
u
mp, 7.5 HP, Low He
a
d with VFD
T
– D
ua
l P
u
mp, 7.5 HP, High He
a
d with VFD
Q
– D
ua
l P
u
mp, 10 HP with VFD
R
– D
ua
l P
u
mp, 15 HP with VFD
Z
–
S
peci
a
l order de
s
ign
a
tion
5
– 20
8
/2
3
0-
3
-60
6
– 460-
3
-60
S
EE NEXT PAGE
FOR REMAINDER
OF MODEL NUMBER
NOMENCLATURE
RB
190
318
Summary of Contents for MINIMUM LOAD CONTROL ACCESSORY 30RB060-390
Page 36: ...36 Fig 24 Unit Rigging Label Detail 30RB060 150...
Page 37: ...37 Fig 25 Unit Rigging Label Detail 30RB160 300...
Page 74: ......
Page 75: ......