background image

8:  Clean the butt connector and at least two (2) inches of the wires on 

either side with the alcohol swab (Fig. 15).

9:  Remove the backing paper from the splice insulation tape and center 

on the butt connector along the length of the tape.  Tightly wrap the 

insulation tape around the butt connector and wires (Fig. 16).

10:  Tuck the completed splice behind the media cartridge enhancement 

grid (Fig. 17).

11:  Insert the enhancement module back into the air purifier cabinet and 

reconnect the power and air flow sensor cables.

12:  Replace the door, turn the Infinity

TM

 air purifier power switch to the 

on position, and turn on the power to the heating and cooling system.

Fig. 16

Fig. 17

Fig. 15

Fig. 13

Fig. 14

6:  Crimp the butt connector to the severed media cartridge enhancement grid wire (Fig. 13).  Please note that the grid wires will 

typically be black. 

7:  Crimp the opposite side of the butt connector to the black replacement power supply wire (Fig. 14).  

Copyright Carrier Corp. • 7310 W. Morris St. • Indianapolis, IN 46231        

Printed in China  

     Edition Date: 2/07        

  

Catalog No. IIK63000-C01

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations

 

  Replaces: New

UNIT OPERATION HAZARD

Failure to follow this caution may result in equipment damage or 

improper operation.
At this point it is critical that your hands are clean before applying the 

splice insulation tape around the butt connector.  Dirt and/or oil can 

contaminate the insulation and cause the splice to fail.

CAUTION

UNIT OPERATION HAZARD

Failure to follow this caution may result in 

equipment damage or improper operation.
Make sure the high voltage wire is routed 

behind the horizontal fiberglass rod.

CAUTION