background image

INSTALLING THE NEW POWER SUPPLY:

1:  Strip the red and black replacement power supply 

wires ¼” from ends.

2:  Insert the high voltage wires through the holes in the 

enhancement face (Fig. 10-A).  Make sure the wires 

do not kink or have twists in them.

3:  Mount the new power supply module to the 

enhancement module using the four screws removed 

earlier (Fig. 10-B).

 

NOTE: Make sure the green ground wire runs down 

the groove in the enhancement module face behind 

the power supply enclosure.

4:  Reconnect the green ground wire to the enhancement 

module (Fig. 11).

5:  Crimp the new ¼” quick disconnect terminal onto the 

red replacement power supply wire and connect to the 

ionization array (Fig. 12).  This may require the use 

of needle-nose pliers. 

Fig. 10-A

Fig. 11

Fig. 10-B

Fig. 12

8:  Remove the power supply module from the enhancement 

module by unscrewing the four Phillips head screws (Fig. 9).

 

You are now ready to install the new power supply.

UNIT OPERATION HAZARD

Failure to follow this caution may result in equipment 

damage or improper operation.
Improper wiring will reduce unit performance.

CAUTION

Fig. 9

2 Screws

2 Screws

Reviews: