
1
50XT---A
Infinity
t
15 SEER Single---Packaged Heat Pump
System With Puron
®
(R---410A) Refrigerant
Single Phase
2 to 5 Nominal Tons (Sizes 24---60)
Installation Instructions
EQUIPMENT OPERATION HAZARD
OAT sensor must be field installed. See Accessory
Installation for more details.
!
CAUTION
EQUIPMENT OPERATION HAZARD
This Infinity unit is designed for use with an Infinity User
Interface.
!
CAUTION
NOTE
:
Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS
2
. . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RECEIVING AND INSTALLATION
2--12
. . . . . . . . . . . . . . . . .
Check Equipment
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Identify Unit
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspect Shipment
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Provide Unit Support
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Roof Curb
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slab Mount
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Provide Clearances
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rig and Place Unit
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspection
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rigging/Lifting of Unit
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Select and Install Ductwork
7
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Converting Horizontal Discharge Units to Downflow
(Vertical) Discharge Units
8
. . . . . . . . . . . . . . . . . . . . . . . . . .
Provide for Condensate Disposal
8
. . . . . . . . . . . . . . . . . . . . . .
Install Electrical Connections
9
. . . . . . . . . . . . . . . . . . . . . . . . .
High--Voltage Connections
9
. . . . . . . . . . . . . . . . . . . . . . . . .
Routing Power Leads Into Unit
9
. . . . . . . . . . . . . . . . . . . . . .
Connecting Ground Lead to Ground Screw
9
. . . . . . . . . . . .
Routing Control Power Wires
11
. . . . . . . . . . . . . . . . . . . . .
Accessory Installation
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Special Procedures for 208--v Operation
12
. . . . . . . . . . . . . .
PRE--START--UP
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
START--UP
13--20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit Start--Up
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sequence of Operation
17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check for Refrigerant Leaks
20
. . . . . . . . . . . . . . . . . . . . . . . . .
Start--Up Adjustments
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Checking Cooling and Heating Control Operation
20
. . . . . .
Checking and Adjusting Refrigerant Charge
20
. . . . . . . . . . .
Refrigerant Charge
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A09032
Fig. 1 -- Unit 50XT
No Charge
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low Charge Cooling
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To Use Cooling Charging Charts
20
. . . . . . . . . . . . . . . . . . . .
Indoor Airflow and Airflow Adjustments
20
. . . . . . . . . . . . .
Non--Communicating Emergency Cooling/Heating Mode
20
. .
MAINTENANCE
22--24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air Filter
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Indoor Fan and Motor
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor Coil, Indoor Coil, and Condensate Drain Pan
23
. . . . .
Outdoor Fan
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Controls and Wiring
23
. . . . . . . . . . . . . . . . . . . . . . .
Refrigerant Circuit
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Indoor Airflow
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Metering Devices–TXV & AccuRater
®
Piston
23
. . . . . . . . . . .
Pressure Switches
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Loss--of--Charge Switch
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
High--Pressure Switches
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Copeland Scroll Compressor (Puron
®
Refrigerant)
24
. . . . . . . .
Refrigerant System
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refrigerant
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compressor Oil
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Servicing Systems on Roofs with Synthetic Materials
24
. . . .
Liquid--Line Filter Drier
24
. . . . . . . . . . . . . . . . . . . . . . . . . .
Puron (R--410A) Refrigerant Charging
24
. . . . . . . . . . . . . . .
TROUBLESHOOTING
25
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FINAL CHECKS
26
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CARE AND MAINTENANCE
26
. . . . . . . . . . . . . . . . . . . . . . . .
START--UP CHECKLIST
29
. . . . . . . . . . . . . . . . . . . . . . . . . . . .