Air Purifier Sizes 1620, 1625, 2020, 2025, 2420: Installation Instructions

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

12

RESET PROCEDURE

When the rapid flashing code occurs on the green light, the controls for

the high voltage need to be reset. To reset the controls, the power switch

needs to be turned on and off for three cycles.

1. Turn off power by depressing the power switch.
2. Wait approximately 2 seconds before turning the power back on.
3. Wait approximately 2 seconds before turning the power off.

4. Repeat Steps 2 and 3 for two more on/off cycles.
5. After  the  three  on/off  cycles  are  completed,  turn  on  power  by

depressing  the  power  switch  on.  The  rapid  flashing  code  on  the

green light should no longer be displayed. If the rapid flashing code

on the green light is still displayed, repeat Steps 1 through 5.

By resetting the air purifier controls the issue with air purifier will need

to be addressed by cleaning or servicing the air purifier.

Table 3 – Start-Up Error Codes

INDICATOR LIGHT CODE

 EXPLANATION

POSSIBLE CAUSE

RECOMMENDED ACTION

2 FLASHES

Filter ground circuit fault 

No filter installed

Place filter in air purifier.

Filter installed incorrectly.

Install filter in correct orientation as 

indicated by airflow direction

arrows on cabinet and filter.

Wrong type of filter installed

Install a genuine air purifier

replacement filter.

Wet filter

Call service to locate and eliminate the 

source of water on the filter and 

replace the filter with a new filter. 

Damaged filter contact spring on door 

assembly

Verify that filter contact springs 

mounted on door are properly

contacting the aluminum contact pads 

on the filter and not

contacting the cabinet or door back.  If 

springs are broken or damaged replace 

the door

assembly.

RAPID FLASHING

(5 flashes per second)

LED Flashes for 10 seconds when AC 

power is turned on indicating a 

previously stored error code code will 

be displayed after 10 seconds. Purifier 

will not operate until cause of error 

condition is rectified and purifier is 

reset.

An error code was registered in the 

purifier controls prior to the purifier 

being turned off.

The purifier controls may be reset 

during the 10 seconds in which the 

LED is flashing rapidly. See the

reset procedure section of this

document for resetting the

electrical controls. If the problem 

persists, follow the actions

recommend in Table 3 for the stored 

error code or call service.

Table 4 – Operating Error Codes

INDICATOR LIGHT CODE

 EXPLANATION

POSSIBLE CAUSE

RECOMMENDED ACTION

4 FLASHES

Ionizer / filter current imbalance

Dirty Filter Enhancement Module 

(FEM).

Clean/service air purifier unit.

Damaged Filter Enhancement

Module (FEM).

Replace the filter enhancement 

module.

5 FLASHES

Over-current fault

Excessively dirty Damaged Filter 

Enhancement Module (FEM) and/or 

filter.

Clean/service air purifier unit. 

Wet Damaged Filter Enhancement 

Module (FEM) and/or filter.

Call service to locate and eliminate the 

source of water in the air

purifier. Verify that the purifier FEM and 

cabinet are clean and replace filter with 

a new filter.

Damaged filter.

Replace the filter element.

Damaged Filter Enhancement

Module (FEM).

Replace the filter enhancement 

module.

Foreign object inside air purifier.

Remove foreign object from air

purifier and insure purifier is clean and 

undamaged.

6 FLASHES

Arc detected

Damaged filter.

Replace the filter element.

Damaged Filter Enhancement Module 

(FEM)

Replace the filter enhancement 

module.  

Foreign object inside air purifier.

Remove foreign object from air

purifier and insure purifier is clean and 

undamaged.

Summary of Contents for DGAPAXX 1620

Page 1: ...nstaller service agency or your distributor or branch for information or assistance The qualified installer or agency must use factory authorized kits or accessories when modifying this product Refer to the individual instructions packaged with the kits or accessories when installing Follow all safety codes Wear safety glasses protective clothing and work gloves Have a fire extinguisher available ...

Page 2: ...dels DGAPAXX1620 DGAPAXX2020 and DGAPAXX2420 include the flow sensor as standard equipment as they are designed primarily to be installed with fan coil air handlers A Flow Sensor Jumper Accessory Kit Table 5 is available should there be a need to use air purifier model DGAPAXX1620 DGAPAXX2020 or DGAPAXX2420 with a furnace that has EAC terminals Electrical Power Fusing Air purifier models DGAPAXX16...

Page 3: ...adhesive backed support foot to the side of the purifier that will be on the floor near the rear of the purifier as shown in Fig 8 Installation Manual Installation Components in accessory bag Door x1 Cabinet x1 Enhancement Module x1 Air Purification Cartridge x1 WARNING ELECTRIC SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained expe...

Page 4: ...sition Air Flow Air Flow Air Flow Air Flow NOTE Mounting on this side requires the cabinet to be rotated 180 for correct air flow This places the hinged end the door at the top of the cabinet and the handle latch at the bottom Downflow 14 Furnace with Top Mount Upflow 14 Furnace with Bottom Mount Horizontal 14 Furnace with Side Mount Plenum Box Upflow Furnace with Plenum Box Horizontal 24 Furnace ...

Page 5: ...cing them with pop rivets may have an adverse effect on air sealing or structural integrity of the furnace 6 Use foam tape or silicone sealant between the furnace and the air purifier cabinet 7 Mounting holes are provided in the air purifier flanges for ductwork and furnace attachment To access the mounting holes on the upstream flange of the purifier adjacent to the incoming power wiring the wiri...

Page 6: ...t connection to the duct and to a furnace controller EAC terminal output The field wiring connection shall be suitable for a maximum possible rating of 90 C of the field wiring terminal box terminals 1 Ensure power has been removed from the heating and cooling system 2 Turn the air purifier power switch off For mounting on furnaces 3 Route the power conduit from the purifier to a knockout on the f...

Page 7: ...1 4 57 22 7 8 581 Outside 5 8 16 Flanges Where Shown B 19 1 8 486 NOTE Weld 3 places in 4 corners 120 VAC INPUT POWER BLK WHT GRN CHASSIS GROUND FURNACE AIR PURIFIER ASSEMBLY LINE 1 IN EAC 1 NEUTRAL IN EAC 2 Sample Furnace Circuit Board LHT OFF DLY ON OFF W2 BLW EAC 1 TERMINAL Y1 DHUM G COM 24V WW1 Y Y2 R TEST TWIN HUM 1 2 3 PL T ACRDJ 0 5 AMP024 V AC FUSE 3 AMP SEC 1 SEC 2 PL1 NEUTRAL L2 1 EA C 2...

Page 8: ... the two in line fuses that are provided with the air purifier must be installed in the fan coil wiring compartment START UP AND OPERATION Final Assembly 1 Install the Filter Enhancement Module FEM into the cabinet insuring that FEM is held firmly in place by the retention springs and that the high voltage connector handle is facing outward Fig 15 A11495 Fig 15 Installing FEM 2 Slide the filter in...

Page 9: ... air purifier cartridge This maintenance reminder can be based on either the TrueSense dirty filter algorithm or time The installer should use their discretion to select the most appropriate option based on the initial system static pressure Maximizing Performance Maximum air purification performance is obtained when the furnace blower is set for continuous operation on the thermostat or Control M...

Page 10: ...ean the FEM it must be completely dry before inserting back into the air purifier Additionally care must be taken when handling the FEM due to the sharp points on the ionizer 5 Slide in enhancement module 6 Replace the air purifier door 7 Turn the air purifier switch to the on position 8 Turn heating and cooling system power on TROUBLESHOOTING The air purifier is equipped with a power indicator li...

Page 11: ...lem reoccurs Misaligned or damaged purifier door Insure that door is undamaged and properly installed on purifier cabinet Damaged or disconnected incoming power wiring Call for service ON continuously Air purifier on Normal operation when airflow is present FLASHING 1 flash every 4 seconds Standby Mode Normal operation when airflow is not present for models with flow sensor Ions detected in airflo...

Page 12: ...e filter and not contacting the cabinet or door back If springs are broken or damaged replace the door assembly RAPID FLASHING 5 flashes per second LED Flashes for 10 seconds when AC power is turned on indicating a previously stored error code code will be displayed after 10 seconds Purifier will not operate until cause of error condition is rectified and purifier is reset An error code was regist...

Page 13: ...lacement Filters Replacement Component Kits and Accessories Air Purifier Model DGAPAXX 1625 2025 1620 2020 2420 Filter Enhancement Module FEM KIT140000 KIT141000 KIT142000 KIT143000 KIT144000 Front Door including Power Supply KIT156000 KIT157000 KIT156000 KIT157000 KIT158000 Flow Sensor KIT160000 Included as standard with Models DGAPAXX1620 DGAPAXX2020 and DGAPAXX2420 Flow Sensor Bypass KIT161000 ...

Reviews: