Faults Occurring While in AUTO Mode
(L/R) HPR>41F (5C) AFTER 4 HR -
The mix
temperature in the hopper was above 41°F (5°C)
more than four hours.
(L/R) BRL>41F (5C) AFTER 4 HR -
The mix
temperature in the freezing cylinder (barrel) was
above 41°F (5°C) more than four hours.
(L/R) HPR>41F (5C) AFTER PF -
The mix
temperature in the hopper was above 41°F (5°C)
more than four hours following a power failure.
(L/R) BRL>41F (5C) AFTER PF -
The mix
temperature in the freezing cylinder (barrel) was
above 41°F (5°C) more than four hours following a
power failure.
(L/R) HPR>45F (7C) AFTER 1 HR -
The mix
temperature in the left or right hopper was above
45
_
F (7
_
C) more than one hour.
(L/R) BRL>45F (7C) AFTER 1 HR -
The mix
temperature in the left or right freezing cylinder
(barrel) was above 45
_
F (7
_
C) more than one hour.
(L/R) HPR>59F (15C) -
The mix temperature in the
hopper exceeded 59°F (15°C).
(L/R) BRL>59F (15C) -
The mix temperature in the
freezing cylinder (barrel) exceeded 59°F (15°C).
Heat Cycle Summary
The HEAT CYCLE SUMMARY screen displays the
hours since the last heat cycle, the hours since the
product temperature was above 150
_
F (65.6
_
C),
and the number of heat cycles completed since the
last brush clean date.
HEAT CYCLE SUMMARY
HRS SINCE HC
0
HRS SINCE 150
0
HC SINCE BC
0
Heat Cycle Data
The HEAT CYCLE DATA screen contains a record
of up to 366 heat treatment cycles. The most recent
heat cycle data will be shown first.
Each heat cycle record has three screens. The first
screen displays the month and day of the heat cycle,
the start time and end time, and the fault description.
The bottom line displays the record number and
indicates if a power failure occurred during the heat
cycle (POWER FAILURE IN HC).
HEAT TREAT CYCLE
01/01
02:00
05:14
NO FAULT FOUND
1
Touch the UP arrow symbol to advance forward
through the data pages. Touch the DOWN arrow
symbol to reverse the page direction.
Hopper and barrel temperature records for each side
of the freezer are displayed in the second and third
screens. The second screen shows the left side (L)
side of the freezer.
The third screen shows the right side (R) of the
freezer.
The top line of these screens shows the hopper (H)
and barrel (B) temperatures recorded at the end of
the Heat Treat Cycle and indicates the side (L or R)
of the freezer.
The remaining lines indicate the following:
HEAT
= Total time for the hopper (h) and barrel (b)
to reach 150.9°F (66.1°C).
OVER
= Total time the hopper (h) and barrel (b)
temperature was above 150°F (65.6°C).
COOL
= Total time the hopper (h) and barrel (b)
temperature was above 41°F (5°C) during the COOL
phase.
PEAK
= Highest temperature reading for the hopper
(h) and barrel (b) during the Heat Treatment Cycle.
Summary of Contents for C708
Page 1: ...Models C708 C709 C716 C717 Heat Treatment Soft Serve Freezers Service Manual 059061 S 6 15 05 ...
Page 2: ......
Page 6: ...Table of Contents Models C708 C709 C716 C717 Notes ...
Page 22: ...16 Introduction Models C708 C709 C716 C717 Notes ...
Page 49: ...43 Models C708 C709 C716 C717 Systems Controls and Operations C708 C709 Control Overview ...
Page 50: ...44 Systems Controls and Operations Models C708 C709 C716 C717 C716 C717 Control Overview ...
Page 53: ...47 Models C708 C709 C716 C717 Systems Controls and Operations Refrigeration Schematic ...
Page 70: ...64 Troubleshooting Models C708 C709 C716 C717 Notes ...
Page 73: ...67 Models C708 C709 C716 C717 Parts Notes ...
Page 74: ...68 Parts Models C708 C709 C716 C717 Model C708 Exploded View ...
Page 78: ...72 Parts Models C708 C709 C716 C717 Model C709 Exploded View ...
Page 82: ...76 Parts Models C708 C709 C716 C717 Model C716 Exploded View ...
Page 86: ...80 Parts Models C708 C709 C716 C717 Model C717 Exploded View ...
Page 133: ...C708 C709 057010 27 Rev 6 05 ...
Page 134: ...C708 C709 057010 33 Rev 6 05 ...
Page 135: ...C708 C709 057010 40 Rev 6 05 ...
Page 136: ...C708 C709 057010 58 Rev 6 05 ...
Page 137: ...Model C716 059900 27 Rev 2 06 ...
Page 138: ...Model C716 059900 27 Inset 1 2 06 ...
Page 139: ...Model C716 059900 27 Inset 2 2 06 ...
Page 140: ...Model C716 059900 33 Rev 2 06 ...
Page 141: ...Model C716 059900 40 Rev 2 06 ...
Page 142: ...Model C716 059900 58 Rev 2 06 ...
Page 143: ...Model C717 059901 27 6 05 ...
Page 144: ...Model C717 059901 27 Inset 1 6 05 ...
Page 145: ...Model C717 059901 27 Inset 2 6 05 ...
Page 146: ...Model C717 059901 33 6 05 ...
Page 147: ...Model C717 059901 40 6 05 ...
Page 148: ...Model C717 059901 58 6 05 ...