Models C708/C709/C716/C717
Introduction
Model C709 Specifications
Freezing Cylinder
One, 3.4 quart (3.2 liter)
Mix Hopper
One, 20 quart (18.9 liter)
Beater Motor
One, 1.5 hp
Refrigeration Unit
One, approximately 9,500 btu/hr compressor.
Refrigerant R404A.
Electrical
One dedicated connection.
Electrical
Maximum
Fuse Size
Minimum
Circuit Ampacity
208-230/60/1 Air
30
22
208-230/60/3 Air
15
13
220-240/50/1 Air
20
18
220-240/380-415/50/3 Air
10
8
This unit may be manufactured in other electrical
characteristics. Refer to the local Taylor Distributor
for availability. (For exact electrical information,
always refer to the data label of the unit.)
Air Cooled
Clearance: A minimum of 6” (152 mm) is required on
both sides, and the back of the unit placed against
the wall to prevent recirculation of warm air. An
optional air discharge chute is available to direct
heated air exhaust upward. No clearance is required
on the right side if the air discharge chute is used.
Water Cooled
Water inlet and drain connections on the right side
or under the side of the base, 3/8” FPT.
Dimensions
Width: 18-1/4” (464 mm)
Height: 33-7/8” (860 mm)
Depth: 34” (864 mm)
Floor Clearance: Rests on a plastic pad directly on
counter top.
Approximate Weights
Net: 335 lbs. (152.0 kgs)
Crated: 375 lbs. (170.1 kgs)
Volume: 30.6 cu. ft. (0.86 cu m)
Note: Shown with optional air discharge chute.
Figure 2
Summary of Contents for C708
Page 1: ...Models C708 C709 C716 C717 Heat Treatment Soft Serve Freezers Service Manual 059061 S 6 15 05 ...
Page 2: ......
Page 6: ...Table of Contents Models C708 C709 C716 C717 Notes ...
Page 22: ...16 Introduction Models C708 C709 C716 C717 Notes ...
Page 49: ...43 Models C708 C709 C716 C717 Systems Controls and Operations C708 C709 Control Overview ...
Page 50: ...44 Systems Controls and Operations Models C708 C709 C716 C717 C716 C717 Control Overview ...
Page 53: ...47 Models C708 C709 C716 C717 Systems Controls and Operations Refrigeration Schematic ...
Page 70: ...64 Troubleshooting Models C708 C709 C716 C717 Notes ...
Page 73: ...67 Models C708 C709 C716 C717 Parts Notes ...
Page 74: ...68 Parts Models C708 C709 C716 C717 Model C708 Exploded View ...
Page 78: ...72 Parts Models C708 C709 C716 C717 Model C709 Exploded View ...
Page 82: ...76 Parts Models C708 C709 C716 C717 Model C716 Exploded View ...
Page 86: ...80 Parts Models C708 C709 C716 C717 Model C717 Exploded View ...
Page 133: ...C708 C709 057010 27 Rev 6 05 ...
Page 134: ...C708 C709 057010 33 Rev 6 05 ...
Page 135: ...C708 C709 057010 40 Rev 6 05 ...
Page 136: ...C708 C709 057010 58 Rev 6 05 ...
Page 137: ...Model C716 059900 27 Rev 2 06 ...
Page 138: ...Model C716 059900 27 Inset 1 2 06 ...
Page 139: ...Model C716 059900 27 Inset 2 2 06 ...
Page 140: ...Model C716 059900 33 Rev 2 06 ...
Page 141: ...Model C716 059900 40 Rev 2 06 ...
Page 142: ...Model C716 059900 58 Rev 2 06 ...
Page 143: ...Model C717 059901 27 6 05 ...
Page 144: ...Model C717 059901 27 Inset 1 6 05 ...
Page 145: ...Model C717 059901 27 Inset 2 6 05 ...
Page 146: ...Model C717 059901 33 6 05 ...
Page 147: ...Model C717 059901 40 6 05 ...
Page 148: ...Model C717 059901 58 6 05 ...