5 - CODIFICATION
Fan motor speed wiring
-
Without filter
V
G3
W G4
-
Without
RIGHT
A
125 mm ø fresh air spigot only
B
8.5l/s (30 m
3
/h)
C
17-44 l/s (21/28/36) 60-160 m
3
/h
(75/100/130)
E
Motorised fresh air valve adapter ø
125 mm
J
125 mm ø fresh air spigot only
LEFT
K
8.5l/s (30 m
3
/h)
L
17-44 l/s (21/28/36) 60-160 m
3
/h
(75/100/130)
N
Motorised fresh air valve adapter ø
125 mm
-
Without
A
NTC
B
HDB
C
W Plastic cover alone
D
NTC + IAQ card
E
Terminal block 6 speeds with plastic box
F
E + relay
G
E + relay + fuse holder
K
NTC + fuse holder
L
NTC + IAQ card + fuse holder
M
HDB + fuse holder
N
W fuse holder
P
W relay
Q
W fuse relay
R
E + fuse holder
S
Electric box
T
S + fuse holder
U
S + relay
V
S + fuse relay
W C + fuse holder
X
C + relay
Y
C + relay + fuse holder
2
Without ( 6 speeds)
3
W Plastic cover alone ( 6 speeds)
4
W fuse holder ( 6 speeds)
5
W relay ( 6 speeds)
6 W fuse relay ( 6 speeds)
7
3+ fuse holder ( 6 speeds)
8
3 + relay ( 6 speeds)
9
3+ relay + fuse holder ( 6 speeds)
B
Modular unit with 2 supply air spigots
C
Modular unit with 3 supply air spigots
G
Modular unit with 1 supply air spigot at the end
(in-line configuration)
H
Modular unit with 1 supply air spigot at the side
(opposite coil)
J
Modular unit with 4 supply air spigots
K
Modular unit with 5 supply air spigots
M Return air plenum 1 spigot and modular unit 1 supply
air spigot (in-line configuration)
N
Return air plenum 1 spigot and modular unit 1 supply
air spigot (U-shape configuration)
P
Return air plenum 2 spigots and modular unit 2
supply air spigots
Q
Return air plenum 3 spigots and modular unit 3
supply air spigots
R
Return air plenum 4 spigots and modular unit 4
supply air spigots
S
Return air plenum 5 spigots and modular unit 5
supply air spigots
T
Compact unit with 1 return air spigot and 1 supply air
spigot
U
Compact unit with 2 return air spigots and 2 supply
air spigots
V
Compact unit with 3 return air spigots and 3 supply
air spigots
NOTE: Terminal 1 = highest speed, Terminal 6 = lowest speed.
Fan set
Codification (last digit)
or option 600
Red wire
Grey wire
Black wire
Wire marked L
Terminal marking (standard wiring), option 600 not selected
and option 570 = NTC or HDB
A
2 pipes right
B
2 pipes left
C
4 pipes right
D
4 pipes left
L
2 pipe/2 wire right 1 x 500W (42 EM
05/09/10/19)
M 2 pipe/2 wire left 1 x 500W (42 EM
05/09/10/19)
N
2 pipe/2 wire right 1 x 800W (42 EM
05/09/10/19)
P
2 pipe/2 wire left 1 x 800W (42 EM
05/09/10/19)
Q
2 pipe/2 wire right 1000W (1 x 1000
42EM 05/09/10/19 & 2 x 500 42EM
21/22/23/29/31/32/33/39 )
R
2 pipe/2 wire left 1000W (1 x 1000
42EM 05/09/10/19 & 2 x 500 42EM
21/22/23/29/31/32/33/39 )
S
2 pipe/2 wire right 1600W (1 x 1600
42EM 05/09/10/19 & 2 x 800 42EM
21/22/23/29/31/32/33/39 )
T
2 pipe/2 wire left 1600W (1 x 1600
42EM 05/09/10/19 & 2 x 800 42EM
21/22/23/29/31/32/33/39 )
U
2 pipe/2 wire right 2000W (2 x 1000W
42EM 22/23/29/32/33/39)
V
2 pipe/2 wire left 2000W (2 x 1000W
42EM 22/23/29/32/33/39)
W 2 pipe/2 wire right 3200W (2 x 1600W
42EM 22/23/29/32/33/39)
X
2 pipe/2 wire left 3200W (2 x 1600W
42EM 22/23/29/32/33/39)
0
0
5
9
1
1
0
9
2
1
2
2
2
2
3
9
3
1
3
2
3
3
3
9
Product type
Size
Modification
code
Coils
Supply and return air plenum
Valv
es
Valv
e motors
Contr
ol
Sensors
Filter and access
Fr
esh air
Motor wiring
Product reference
4
2
E
M
0
5
E
A
T
-
0
-
-
B
-
Q
Digit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
{
Variable-speed
LEC motor
-
Without
A Condensate pump
B 2-way valve + condensate pump
C 2-way valve
D 4-way valve
E 4-way valve + condensate pump
F
2-way valve + flexible
condensate pump
G
4-way valve + flexible
condensate pump
J
2-way valve + flexible piping
K
4-way valve + flexible piping
-
Without
A
230 V on/off
B
24 V on/off
C 230 V 3 points
D 24 V 3 points
E
24 V (modulating 0-10 V)
-
Without
A
Return air sensor
B
Supply air sensor
C
Change-Over water sensor
D
A + B
E
A + B + C
F
A + C
G
B + C
H
CO
2
sensor
J
A + CO
2
K
B + CO
2
L
C + CO
2
M
A + B +CO
2
N
A + C + CO
2
P
B + C + CO
2
Q
A + B + C + CO
2