Single--Packaged Gas Furnace/Air Conditioner

System with Puron

R

(R--410A) Refrigerant

Single-- And Three--Phase Units Sizes 018--060

Installation Instructions

NOTE

: Read the entire instruction manual before starting the

installation.

NOTE

: Installer: Make sure the Owner’s Manual and Service

Instructions are left with the unit after installation.

TABLE OF CONTENTS

Page

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RECEIVING AND INSTALLATION

2--12

. . . . . . . . . . . . . . . .

Check Equipment

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Identify Unit

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Inspect Shipment

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Provide Unit Support

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Roof Curb

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Slab Mount

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ground Mount

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Field Fabricate Ductwork

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Provide Clearances

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Rig and Place Unit

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Inspection

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Use of Rigging Bracket

6

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Condensate Drain

8

. . . . . . . . . . . . . . . . . . . . . . . . . .

Install Flue Hood

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Install Gas Piping

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Install Duct Connections

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Configuring Units for Downflow (Vertical)

Discharge

9--10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Install Electrical Connections

11

. . . . . . . . . . . . . . . . . . . . . . .

High--Voltage Connections

11

. . . . . . . . . . . . . . . . . . . . . . .

Special Procedures for 208--V Operation

11

. . . . . . . . . . . . .

Control Voltage Connections

11

. . . . . . . . . . . . . . . . . . . . . .

Heat Anticipator Setting

12

. . . . . . . . . . . . . . . . . . . . . . . . .

Transformer Protection

12

. . . . . . . . . . . . . . . . . . . . . . . . . .

PRE--START--UP

12--13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP

13--19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Check for Refrigerant Leaks

13

. . . . . . . . . . . . . . . . . . . . . . . .

Start--Up Heating & Make Adjustments

13

. . . . . . . . . . . . . . .

Check Heating Control

13

. . . . . . . . . . . . . . . . . . . . . . . . . .

Check Gas Input

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Adjust Gas Input

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Check Burner Flame

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Airflow and Temperature Rise

14

. . . . . . . . . . . . . . . . . . . . .

Heating Sequence of Operation

18

. . . . . . . . . . . . . . . . . . . .

Limit Switches

18

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Rollout Switch

18

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Start--Up Cooling & Make Adjustments

18

. . . . . . . . . . . . . . .

Checking Cooling Control Operation

18

. . . . . . . . . . . . . . .

Checking & Adjusting Refrigerant Charge

18

. . . . . . . . . . .

Indoor Airflow and Airflow Adjustments

19

. . . . . . . . . . . .

Cooling Sequence of Operation

19

. . . . . . . . . . . . . . . . . . . .

MAINTENANCE

23--26

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air Filter

23

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Indoor Blower and Motor

23

. . . . . . . . . . . . . . . . . . . . . . . .

Flue Gas Passageways

23

. . . . . . . . . . . . . . . . . . . . . . . . . . .

A99338

Fig. 1 -- Unit 48ES

(Low NOx Model Available)

Induced Draft (Combustion Air) Blower

24

. . . . . . . . . . . . .

Limit Switch

24

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Burner Ignition

24

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Main Burners

24

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Outdoor Coil, Indoor Coil, & Condensate Drain Pan

24

. . .

Outdoor Fan

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical Controls and Wiring

25

. . . . . . . . . . . . . . . . . . . .

Refrigerant Circuit

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gas Input

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Evaporator Airflow

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Puron Items

25--26

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

27

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP CHECKLIST

27

. . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Installation and servicing of this equipment can be hazardous due to

mechanical and electrical components. Only trained and qualified

personnel should install, repair, or service this equipment.
Untrained personnel can perform basic maintenance functions such

as cleaning and replacing air filters. All other operations must be
performed by trained service personnel. When working on this

equipment, observe precautions in the literature, on tags, and on
labels attached to or shipped with the unit and other safety

precautions that may apply.
Follow all safety codes. Installation must be in compliance with
local and national building codes. Wear safety glasses, protective

clothing, and work gloves. Have fire extinguisher available. Read
these instructions thoroughly and follow all warnings or cautions

included in literature and attached to the unit.

Summary of Contents for 48ES

Page 1: ...Start Up Cooling Make Adjustments 18 Checking Cooling Control Operation 18 Checking Adjusting Refrigerant Charge 18 Indoor Airflow and Airflow Adjustments 19 Cooling Sequence of Operation 19 MAINTENAN...

Page 2: ...t for shipping damage while unit is still on shipping pallet If unit appears to be damaged or is torn loose from its anchorage have it examined by transportation inspectors before removal Forward clai...

Page 3: ...UNGROUNDED SURFACES POWER ENTRY SIDE 36 00 914 0 UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES POWER ENTRY SIDE 42 00 1066 8 LEGEND CG Center of Gravity COND Condensor EVAP Evaporator...

Page 4: ...m BETWEEN UNITS POWER ENTRY SIDE 42 00 1066 8 UNIT AND UNGROUNDED SURFACES POWER ENTRY SIDE 36 00 914 0 UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES POWER ENTRY SIDE 42 00 1066 8 LEGEN...

Page 5: ...eck pan Short Support CTyp G E F G D E A05308 UNIT SIZE ODS CATALOG NUMBER A IN MM B IN MM C IN MM D IN MM E IN MM F IN MM G IN MM 48ES018 036 CPRFCURB006A00 8 203 11 279 16 1 2 419 28 3 4 730 30 3 8...

Page 6: ...eered and designed to be installed only on Small Packaged Products This bracket is to be used to rig lift a Small Packaged Product onto roofs or other elevated structures Prior to initial use and at m...

Page 7: ...Size in 20x24x1 508x610x25 mm 24x30x1 610x762x25 mm 24x36x1 610x914x25 mm Table 1 Physical Data Con t Unit 48ES UNIT SIZE 048090 048115 048130 060090 060115 060130 NOMINAL CAPACITY ton 4 4 4 5 5 5 OPE...

Page 8: ...sure that the outlet of the trap is at least 1 in 25 4 mm lower than the drain pan condensate connection to prevent the pan from overflowing See Fig 7 Prime the trap with water When using agravel apro...

Page 9: ...joint when making pipe connections Use only pipe dope that is resistant to action of liquefied petroleum gases as specified by local and or national codes Never use Teflon tape 4 Install sediment tra...

Page 10: ...nd power up unit NOTE The design and installation of the duct system must be in accordance with the standards of the NFPA for installation of nonresidence type air conditioning and ventilating systems...

Page 11: ...when the standard power and low voltage entry points are used See Fig 3 and 4 for acceptable location See unit wiring label and Fig 11 for reference when making high voltage connections Proceed as fol...

Page 12: ...rate compressor or provide any electric power to unit unless compressor terminal cover is in place and secured 3 Do not remove compressor terminal cover until all electrical sources are disconnected a...

Page 13: ...e Refer to unit rating plate for required charge Step 2 Start up Heating and Make Adjustments Complete the required procedures given in the Pre Start Up section before starting the unit Do not jumper...

Page 14: ...h only a minor change in the manifold pressure is required Observe manifold pressure and proceed as follows to adjust gas input 1 Removecoverscrewoverregulatoradjustmentscrew ongas valve 2 Turn regula...

Page 15: ...15 A07230 Fig 15 208 230 1 60 Wiring Diagram 48ES...

Page 16: ...16 A07232 Fig 16 208 230 3 60 Wiring Diagram 48ES...

Page 17: ...17 A07231 Fig 17 460 3 60 Wiring Diagram 48ES...

Page 18: ...e rollout switch reaches the maximum allowable temperature the control circuit trips closing the gas valve and stopping gas flow to the burners The indoor evaporator fan motor IFM and induced draft mo...

Page 19: ...tions and adjusted properly Airflow can be changed using the User Interface ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death Disconnect electrical power...

Page 20: ...a gauge to the service port 2 Measure the Liquid line temperature by attaching a temperature sensing device to it 3 Insulate the temperature sensing device so that the Outdoor Ambient doesn t affect...

Page 21: ...9 994 917 837 702 570 442 Heating Rise oF C 54 30 58 32 62 34 68 38 NA NA NA NA NA Medium Watts 503 491 479 461 450 436 418 404 389 CFM 1320 1244 1162 1081 1005 897 767 662 541 Heating Rise oF C 51 28...

Page 22: ...729 1647 1496 Heating Rise oF C 31 17 32 18 33 18 34 19 36 20 37 21 39 22 41 23 45 25 48ES N 060115 35 65 19 36 Low1 Watts 786 769 754 736 722 705 684 658 616 CFM 2027 1960 1901 1821 1759 1693 1616 15...

Page 23: ...necessary AIR FILTER IMPORTANT Never operate the unit without a suitable air filter in the return air duct system Always replacethe filterwith thesame dimensional size and type as originally installed...

Page 24: ...ses Observe the main burner flames and adjust if necessary Removal of Gas Train To remove the gas train for servicing 1 Shut off main gas valve 2 Shut off power to unit and install lockout tag 3 Remov...

Page 25: ...function has occurred check each electrical component with the proper electrical instrumentation Refer to the unit wiring label when making these checks REFRIGERANT CIRCUIT Annually inspect all refrig...

Page 26: ...t extreme high pressure The relief port has an operating range between 550 26 34 kPa and 625 psi 29 93 kPa differential pressure The Copeland scroll compressor uses Mobil 3MAF POE oil Copeland Ultra 2...

Page 27: ...ow side with 550 psig low side retard S Use hoses with 700 psig service pressure rating S Leak detectors should be designed to detect HFC refrigerant S Puron as with other HFCs is only compatible with...

Page 28: ...or Replace and determine cause Insufficient line voltage Determine cause and correct Blocked outdoor coil Determine cause and correct Defective run start capacitor Determine cause and replace Faulty o...

Page 29: ...te ensure temperature rise is correct Ensure unit s external static pressure is within application guide lines Limit switch faults LED 2 flashes High temperature limit switch is open Check the operati...