background image

5

49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64

33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

1

MONITOR

SET

ZONE

ALL

CENTER
LOCKED

AUX. TYPE

TIMER No.

STANDBY

FILTER

ON

OFF

MODE
FAN ONLY

COOL

DRY

HEAT

AUTO

UNIT

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

FAN

AUTO

HIGH

MED.

LOW

FIX

TEMP.

CHECK

1
2

˚C

LOUVER
MANUAL

Indicated while the discharge 
louver automatically operates.
(Display disappears when the 
operation stops.)

LOUVER indication

Indicated when operation is 
disabled in case of using the air 
conditioner as Multi type.

STANDBY indication

Indicated when operation by 
weekly timer or timer on the market 
becomes available.

TIMER indication

Indicates the operation status of the remote controller 
at indoor unit side.

Last-push priority/Center/Locked indication

Indicates the selected fan mode.

FAN indication

Indicates the selected unit No.

UNIT No. indication

Indicates the connected unit No. and 
the operation status.

Operation monitor indication

“MONITOR” is displayed in normal 
time. “SET” is displayed with flashing 
while setting Start/Stop/every setting.

MONITOR/SET indication

Indicates the selected zone No.

ZONE No. indication

Indicates that start/stop/every set up 
operations are performed for all units, 
zone, or individual unit.

ALL/ZONE/UNIT indication

Indicates that the air conditioner of 
which unit No. is displayed is ON or OFF.

ON/OFF indication

Indicates the selected operation mode.

MODE indication

Indicates the selected 
set up temperature.

TEMP. indication

Indicated while the 
mode is CHECK mode.

CHECK indication

When this indication goes 
on, clean the air filter. 
(For details, see p.17.)

FILTER indication

Indication section

Indication examples show all the contents for explanation.
In practice, the selected contents are displayed.

(NOTE)

Setting of last-push priority/Center/Locked are as described below.

Last-push priority/

Center/

Locked indication

Operation propriety of remote controller

at indoor unit side and indication

“CENTRAL” indication

No display

(Last-push priority)

Operable from both central remote controller and remote controller at indoor
unit side.

Goes off

CENTER

Contents set from central remote controller are fixed. Start/Stop and timer
set up only can be operated from remote controller at indoor unit side.

Goes on

LOCKED

Contents set from central remote controller are fixed, and the air conditioner
stops. Operation from remote controller at indoor unit side is disabled.

Flashes

Summary of Contents for 40RC003603

Page 1: ...d Functions 3 Names and Operation of Each Part 4 Entering to Zone 7 Cancel of Zone Entering 8 Operation 9 Start Stop Operation for ALL ZONE 13 Timer Operation 14 Set Up Method of Operation Mode 15 Adj...

Page 2: ...d or by specialist Never insert metals such as a pin or wire into a hole or clearance It may cause a fire or electric shock Never handle the switches with wet hands It may cause an electric shock Do n...

Page 3: ...ely controlled from the separated positions Remote controller management at indoor unit side Three functions last push priority mode center mode or operation lock mode can be selected Filter sign FILT...

Page 4: ...gle remote controller Two remote controllers or Single remote controller Two remote controllers Max 16 units Max 16 units System 1 Central remote controller System 2 System 3 System 4 System 5 System...

Page 5: ...e No ZONE No indication Indicates that start stop every set up operations are performed for all units zone or individual unit ALL ZONE UNIT indication Indicates that the air conditioner of which unit...

Page 6: ...ion LOUVER button Used in servicing Do not operate this button in normal time For symptom check the Code No can be observed For details see p 18 CHECK button Resets Erases FILTER indication FILTER RES...

Page 7: ...T button the flashing Unit No in the operation monitor indication part goes on Repeat steps 3 and 4 and select Unit No 3 4 and 5 5 When ZONE SET ENTER button is pushed the contents are entered Unit No...

Page 8: ...n the corresponding zone go on 1 is indicated at shipment from the factory Unit No 1 is set to Zone No 1 3 Pushing UNIT button matches Unit No to be canceled The matched No is indicated in Unit No ind...

Page 9: ...AN AUTO TEMP C LOUVER LOUVER FAN TEMP MODE MONITOR SET ALL ZONE ZONE UNIT ON CENTER LOCKED CHECK ZONESET ENTER SELECT OFF TIMERON FILTERRESET 49 64 33 48 17 32 1 SET CENTER ON MODE COOL ON UNIT 2 3 4...

Page 10: ...T No indication Last push priority CENTER LOCKED 3 Selection of ZONE No Push ZONE button to match to ZONE No to be set Unit No entered in the indicated zone is indi cated in the Operation monitor indi...

Page 11: ...OCKED Push CENTER LOCKED button to match indication to No indication Last push prior ity CENTER or LOCKED NOTE Every pushing the button indication changes in the following order 6 SET Match MODE FAN T...

Page 12: ...button OFF indication goes on END Selection of MONITOR SET Push MONITOR SET button again to match to MONITOR SET indication goes off and MONITOR indication goes on Indication returns automatically to...

Page 13: ...L ZONE button to match to ZONE ZONE ON and OFF indications flash 3 Selection of ZONE No Push ZONE button to match to the ZONE No to be started or stopped All the entered UNIT Nos of in the Zone are in...

Page 14: ...lection of ALL ZONE UNIT Push ALL ZONE button to select ALL ZONE or UNIT for the indoor units to be set NOTE Every pushing the button indication changes in the following order ALL ZONE UNIT When ALL i...

Page 15: ...ion changes in the following order Indication differs according to Model type 5 Selection of FAN Push FAN button to select the Fan mode NOTE Every pushing the button indication changes in the followin...

Page 16: ...utton LOUVER indication goes off Push MONITOR SET button again to match MONITOR Then the setting completes The discharge louver stops soon REQUIREMENT Do not move the discharge louver directly with ha...

Page 17: ...t indicated If the power of the air conditioner is turned off the extended operation time is held Fire alarm signal Connecting a fire alarm signal of the fire alarm panel all the connected units stop...

Page 18: ...g status of trouble Check procedure Push CHECK button for 1 or 2 seconds CHECK indication appears The unit number is indicated and then the Check code number and alphabat is displayed in the TEMP indi...

Page 19: ...onsumption Max 2W Use ambient temp Humidity 0 to 40 C up to 80 However no dewing Dimension 180 x 120 x 65 6 Width x Height x Depth Mass 420g External View Specifications and external view of this prod...