background image

 

4

 

Accessories

 

* Isolation relay required. 

† Consult low-ambient controller Installation Instructions for application.
‡ Hard shutoff TXV requires compressor start assist on reciprocating compressors.

N/A — Not applicable in this application. 

 

ORDERING NUMBER

DESCRIPTION

KAAWS0101AAA

 

Winter Start Control — All Sizes

 

KAATD0101TDR

 

Time-Delay Relay — All Sizes

 

KAAFT0101AAA

 

Evaporator Freeze Thermostat† — All Sizes

 

KHAIR0101AAA

 

Isolation Relay† — All Sizes

 

KSACY0101AAA

 

Cycle Protector — Sizes 024, 036

 

Standard

 

Cycle Protector — Sizes 036 (71), 048, 060

 

N/A

 

Compressor Start Assist (Capacitor/Relay) — Sizes 036 (90), 048 (90), 060 (90)

 

KAAHS0601AAA

 

Compressor Start Assist (Capacitor/Relay) — Size 024

 

KAAHS0401AAA

 

Compressor Start Assist (Capacitor/Relay) — Sizes 036 (70), 048 (70)

 

KAACS0201PTC

 

Start Assist (PTC) — Sizes 036, 048 (70)

 

Standard

 

Start Assist (PTC) — Size 024

 

N/A

 

Start Assist (PTC) — Sizes 036, 048 (90), and 060 (90)

 

Standard

 

Crankcase Heater — All Sizes

 

KSASH1101COP

 

Sound Blanket — Size 024

 

KSASH2001CYL

 

Sound Blanket — Sizes 036 (70, 90); 048; 060 

 

KHAOT0301FST

 

Outdoor Thermostat — All Sizes

 

KHAOT0201SEC

 

Secondary Outdoor Thermostat — All Sizes

 

KHATX1001HSO‡

 

TXV (Hard Shutoff) — Size 024

 

KHATX1201HSO‡

 

TXV (Hard Shutoff) — Sizes 036

 

KHATX1301HSO

 

TXV (Hard Shutoff) — Size 048

 

KHATX1401HSO

 

TXV (Hard Shutoff) — Size 060

 

KHATX0301RPB

 

TXV (RPB) — Size 024

 

KHATX0501RPB

 

TXV (RPB) — Sizes 036

 

KHATX0601RPB

 

TXV (RPB) — Size 048

 

KHATX0701RPB

 

TXV (RPB) — Size 060

 

Standard

 

Low-Pressure Switch — All Sizes

 

KSAHI0201HPS

 

High-Pressure Switch — All Sizes

 

KHALS0101LLS

 

Liquid Solenoid Valve (LSV) — All Sizes

 

P251-0083

 

Low-Ambient Controller* (RCD) — All Sizes

 

P504-8083S

 

Filter Drier — Bi-flow Sizes 024, 036

 

P504-8163S

 

Filter Drier — Bi-flow Sizes 048, 060

 

32LT660004

 

MotorMaster® Control — All Sizes

 

THERMOSTAT

DESCRIPTION

TSTATCCNHP01-A

 

Thermostat, Auto Changeover, Non-Programmable, 

 

°

 

F/

 

°

 

C, 2-Stage Heat, 1-Stage Cool

 

TSTATCCPHP01-A

 

Thermostat, Auto Changeover, 7-Day Programmable, 

 

°

 

F/

 

°

 

C, 2-Stage Heat, 1-Stage Cool

 

--HH--07AT-215

 

Thermostat, Manual Changeover, Non-Programmable, 

 

°

 

F, 2-Stage Heat, 1-Stage Cool

 

TSTATCCSEN01

 

Outdoor Sensor

Summary of Contents for 38YCB

Page 1: ...nd excess humidity during the cooling season FEATURES BENEFITS Electrical Range Units are offered in single phase 220 240v Three phase units are available in sizes 036 048 and 060 in 400v Size Range T...

Page 2: ...e A coat of modified polyester powder coating is then applied and baked on providing each unit with a hard smooth finish that will last for many years All screws on cabinet exterior are coated for a l...

Page 3: ...Copeland Recip Millennium Scroll Millennium Scroll REFRIGERANT Control Charge Lb Kg 15 ft 22 Piston 4 04 2 2 7 9 3 8 5 3 2 4 7 25 10 9 4 9 10 75 CONDENSER FAN Air Discharge Air Qty CFM L S Motor RPM 5...

Page 4: ...zes KSASH1101COP Sound Blanket Size 024 KSASH2001CYL Sound Blanket Sizes 036 70 90 048 060 KHAOT0301FST Outdoor Thermostat All Sizes KHAOT0201SEC Secondary Outdoor Thermostat All Sizes KHATX1001HSO TX...

Page 5: ...it when the heat pump switches to heating mode SUGGESTED USE All heat pumps where low ambient controller has been added 7 Liquid Solenoid Valve LSV An electrically operated shutoff valve to be install...

Page 6: ...75 C MAX LENGTH Ft 60 C 75 C MAX LENGTH m 60 C 75 C MAX FUSE OR HACR TYPE CKT BKR AMPS Max Min LRA RLA 024 70 230 1 253 207 68 0 11 5 1 4 15 8 14 14 55 39 16 7 11 9 25 036 70 94 0 16 5 1 4 22 2 12 12...

Page 7: ...2 70 5 91 5 91 2 81 5 65 5 65 2 92 5 39 5 39 3 03 5 13 5 13 3 13 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity...

Page 8: ...11 5 6 04 11 1 11 1 6 40 14 13 5 13 5 4 45 13 1 13 1 4 73 12 8 12 8 5 03 12 4 12 4 5 34 11 9 11 9 5 68 11 5 11 5 6 04 11 1 11 1 6 40 Multipliers for Determining the Performance With Other Indoor Secti...

Page 9: ...3 21 3 2 68 20 1 20 1 2 83 18 9 18 9 2 99 17 6 17 6 3 13 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power...

Page 10: ...39 7 33 7 6 47 62 47 8 46 6 4 19 45 8 45 4 4 55 43 9 43 9 4 95 41 9 41 9 5 39 40 0 40 0 5 86 38 0 38 0 6 37 57 47 4 47 4 4 18 45 7 45 7 4 55 43 8 43 8 4 95 42 0 42 0 5 39 40 0 40 0 5 86 38 0 38 0 6 3...

Page 11: ...3 73 1 78 5 26 4 73 2 09 5 91 5 51 2 26 6 61 6 58 2 44 7 41 7 41 2 66 8 26 8 26 2 89 9 14 9 14 3 15 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Heating I...

Page 12: ...r Determining the Performance With Other Indoor Sections Indoor Section Size Heating Indoor Section Size Heating Capacity Power Capacity Power F A B 4AS F B 048 1 00 1 00 FG3ASA 048 1 00 1 03 060 0 99...

Page 13: ...1 57 13 8 12 6 1 77 16 5 14 6 1 98 19 5 17 7 2 20 22 8 22 8 2 46 26 6 26 6 2 76 30 8 30 8 3 11 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Heating Indoo...

Page 14: ...40 3 36 6 3 91 47 8 47 8 4 11 56 7 56 7 4 34 67 3 67 3 4 64 70 1400 18 5 17 1 3 41 23 0 21 1 3 54 27 7 25 3 3 70 33 1 29 4 3 87 39 3 35 7 4 07 46 4 46 4 4 29 55 3 55 3 4 59 65 3 65 3 4 93 1600 18 8 1...

Page 15: ...6 In 152 4mm on one side 12 In 304 8mm on remaining side and 24 In 609 6mm between units for proper airflow 2 Minimum outdoor operating ambient in cooling mode is 55 F 13 C max 125 F 52 C 3 Maximum ou...

Page 16: ...NG HEAT LOSS KW UNIT INTEGRATED HEATING CAPACITY KW Printed in U S A 11 94 OUTDOOR TEMPERATURE C 20 10 0 10 20 30 20 10 40 BASED ON INDOOR ENT AIR AT 21 C AND AT RATED CFM 38YCB024 FB4AS024 38YCB036 F...

Page 17: ...T INTEGRATED HEATING CAPACITY 1000 BTU HR Printed in U S A 11 94 OUTDOOR TEMPERATURE F 10 0 10 20 30 40 50 60 70 80 70 60 50 40 30 20 10 80 38YCB024 FB4AS024 38YCB036 FB4AS036 38YCB048 FB4AS048 38YCB0...

Page 18: ...Condenser fan will be direct drive propeller type discharging air upward Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts...

Page 19: ...19...

Page 20: ...Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Page 20 Catalog No 013 881 Printed in U S A PC...

Reviews: