
11
Heat pump heating performance (S.I.)
See notes on pg. 12.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES
°
C
–16
–8
0
4
8
12
16
20
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
Capacity
Kw
Total
Power
(C)
EDB
L/ S
Total Integ† Kw*
Total Integ† Kw*
Total Integ† Kw*
Total Integ† Kw*
Total Integ† Kw*
Total Integ† Kw*
Total Integ† Kw*
Total Integ† Kw*
38YCB024-70 Outdoor Section With F(A,B)4ASF024 Indoor Section
12
340
3.39
3.12
1.39
4.44
4.04
1.63
5.64
5.08
1.90
6.32
5.90
2.05
7.04
7.01
2.22
7.87
7.87
2.42
8.75
8.75
2.64
9.67
9.67
2.88
380
3.44
3.17
1.41
4.51
4.10
1.65
5.73
5.16
1.91
6.42
5.99
2.06
7.15
7.11
2.22
7.98
7.98
2.42
8.88
8.88
2.64
9.82
9.82
2.88
420
3.49
3.21
1.43
4.56
4.15
1.66
5.80
5.21
1.92
6.49
6.05
2.07
7.22
7.18
2.23
8.06
8.06
2.43
8.97
8.97
2.65
9.93
9.93
2.89
15
340
3.28
3.01
1.41
4.33
3.94
1.66
5.51
4.96
1.94
6.18
5.76
2.10
6.89
6.86
2.27
7.70
7.70
2.47
8.57
8.57
2.70
9.48
9.48
2.95
380
3.33
3.06
1.43
4.39
4.00
1.68
5.60
5.04
1.95
6.28
5.85
2.11
6.99
6.96
2.28
7.82
7.82
2.48
8.70
8.70
2.70
9.63
9.63
2.95
420
3.37
3.10
1.45
4.45
4.05
1.69
5.66
5.09
1.96
6.34
5.91
2.12
7.07
7.03
2.28
7.90
7.90
2.48
8.79
8.79
2.71
9.73
9.73
2.95
18
340
3.16
2.91
1.43
4.21
3.83
1.69
5.38
4.84
1.98
6.04
5.63
2.14
6.74
6.71
2.32
7.54
7.54
2.53
8.39
8.39
2.76
9.28
9.28
3.01
380
3.21
2.95
1.45
4.27
3.89
1.71
5.46
4.92
1.99
6.13
5.71
2.15
6.84
6.81
2.33
7.65
7.65
2.54
8.52
8.52
2.77
9.43
9.43
3.01
420
3.26
3.00
1.47
4.33
3.94
1.72
5.53
4.97
2.01
6.20
5.78
2.17
6.92
6.89
2.34
7.74
7.74
2.54
8.61
8.61
2.77
9.54
9.54
3.02
21
340
3.05
2.80
1.44
4.10
3.73
1.72
5.25
4.73
2.02
5.89
5.49
2.19
6.59
6.56
2.37
7.37
7.37
2.59
8.21
8.21
2.83
9.08
9.08
3.08
380
3.10
2.85
1.47
4.16
3.78
1.74
5.33
4.80
2.03
5.98
5.58
2.20
6.69
6.66
2.38
7.49
7.49
2.59
8.34
8.34
2.83
9.23
9.23
3.08
420
3.14
2.89
1.49
4.21
3.83
1.75
5.39
4.85
2.05
6.06
5.65
2.21
6.77
6.74
2.39
7.58
7.58
2.60
8.44
8.44
2.83
9.35
9.35
3.09
24
340
2.92
2.69
1.46
3.98
3.63
1.75
5.12
4.61
2.06
5.75
5.36
2.23
6.43
6.40
2.42
7.20
7.20
2.64
8.02
8.02
2.89
8.88
8.88
3.14
380
2.98
2.74
1.48
4.04
3.68
1.76
5.19
4.68
2.07
5.84
5.44
2.25
6.53
6.50
2.43
7.32
7.32
2.65
8.15
8.15
2.89
9.03
9.03
3.14
420
3.02
2.78
1.50
4.10
3.73
1.78
5.26
4.73
2.09
5.91
5.51
2.26
6.61
6.58
2.44
7.41
7.41
2.66
8.26
8.26
2.89
9.14
9.14
3.15
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Heating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
F(A,B)4ASF
024
1.00
1.00
FG3ASA
024
0.99
1.05
030
1.00
0.99
—
—
—
38YCB036-70, 90 Outdoor Section With F(A,B)4ASF036 Indoor Section
2
500
5.42
4.98
2.22
7.03
6.40
2.49
8.86
7.98
2.78
9.93
9.26
2.95
11.1
11.0
3.14
12.3
12.3
3.36
13.7
13.7
3.61
15.1
15.1
3.88
560
5.49
5.05
2.26
7.13
6.49
2.52
9.00
8.10
2.80
10.1
9.40
2.97
11.2
11.2
3.14
12.5
12.5
3.36
13.9
13.9
3.60
15.3
15.3
3.87
640
5.60
5.15
2.31
7.26
6.60
2.56
9.15
8.23
2.83
10.2
9.54
2.99
11.4
11.4
3.16
12.7
12.7
3.37
14.1
14.1
3.62
15.6
15.6
3.88
15
500
5.22
4.80
2.25
6.84
6.22
2.54
8.65
7.79
2.84
9.70
9.04
3.02
10.8
10.8
3.21
12.1
12.1
3.44
13.4
13.4
3.69
14.8
14.8
3.97
560
5.30
4.87
2.28
6.94
6.32
2.57
8.78
7.90
2.86
9.84
9.17
3.04
11.0
10.9
3.22
12.2
12.2
3.44
13.6
13.6
3.69
15.0
15.0
3.96
640
5.41
4.97
2.34
7.06
6.43
2.61
8.93
8.03
2.90
10.0
9.32
3.06
11.1
11.1
3.24
12.4
12.4
3.46
13.8
13.8
3.70
15.2
15.2
3.97
18
500
5.02
4.62
2.27
6.65
6.05
2.58
8.44
7.60
2.91
9.46
8.82
3.09
10.6
10.5
3.29
11.8
11.8
3.52
13.1
13.1
3.78
14.4
14.4
4.06
560
5.11
4.69
2.31
6.75
6.14
2.61
8.57
7.71
2.93
9.60
8.95
3.11
10.7
10.7
3.30
12.0
12.0
3.52
13.3
13.3
3.78
14.7
14.7
4.05
640
5.21
4.79
2.37
6.87
6.25
2.66
8.71
7.84
2.96
9.76
9.10
3.13
10.9
10.8
3.32
12.2
12.2
3.54
13.5
13.5
3.79
14.9
14.9
4.06
21
500
4.83
4.44
2.30
6.46
5.88
2.63
8.23
7.40
2.97
9.22
8.60
3.16
10.3
10.2
3.36
11.5
11.5
3.60
12.8
12.8
3.86
14.1
14.1
4.14
560
4.91
4.52
2.34
6.56
5.97
2.66
8.35
7.52
2.99
9.37
8.73
3.18
10.5
10.4
3.38
11.7
11.7
3.61
13.0
13.0
3.86
14.3
14.3
4.14
640
5.02
4.61
2.40
6.68
6.08
2.71
8.49
7.64
3.03
9.53
8.88
3.21
10.6
10.6
3.40
11.9
11.9
3.62
13.2
13.2
3.88
14.6
14.6
4.15
24
500
4.61
4.24
2.33
6.26
5.70
2.67
8.01
7.21
3.03
8.99
8.38
3.22
10.0
9.99
3.44
11.2
11.2
3.68
12.4
12.4
3.95
13.7
13.7
4.23
560
4.70
4.32
2.37
6.36
5.79
2.70
8.14
7.32
3.05
9.13
8.51
3.24
10.2
10.1
3.45
11.4
11.4
3.69
12.7
12.7
3.95
14.0
14.0
4.23
640
4.81
4.42
2.42
6.48
5.90
2.75
8.28
7.45
3.09
9.29
8.66
3.28
10.4
10.3
3.48
11.6
11.6
3.71
12.9
12.9
3.96
14.2
14.2
4.24
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Heating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
F(A,B)4ASF
036
1.00
1.00
FG3ASA
036
0.99
1.01
F(A,B)4AS(F,B)
042
1.00
0.97
—
—
—
Summary of Contents for 38YCB
Page 19: ...19...