(See heating and cooling performance 
tables.) For compressor usage, see 
Compressor data table. 

 

Built-in-Reliability 
Components 

 

— Includes a suction-

tube accumulator that reduces the 
amount of liquid refrigerant that 
reaches the compressor; low-pressure 
switch to stop the compressor if 
refrigerant charge is lost; crankcase 
heater on units with reciprocating 
compressor and all 3-phase units to 
keep compressor oil warm and free of 
refrigerant for maximum lubricity; 
internal compressor relief valve for 
high-pressure protection.

 

Discharge Silencer 

 

— Minimizes low 

frequency sound and pressure 
pulsation generated by compressor 
discharge gas.

 

Defrost Control Board

 

 — 

Incorporates a defrost relay, defrost 
timer, and low-voltage terminations. 

The defrost control is a time and 
temperature initiation/termination 
control which includes 3 field-
selectable time periods of 30, 50, and 
90 minutes. The control includes built-
in 5-minute compressor delay for units 
equipped with scroll compressors (see 
Compressor data table).

 

Weather-Protective Cabinet

 

 — Steel 

is protected with a heavy coating 
commonly called “galvanizing,” and 
treated with a layer of zinc phosphate. 
A coat of modified polyester powder 
coating is then applied and baked-on, 
providing each unit with a hard, 
smooth finish that will last for many 
years.

All screws on cabinet exterior are 
coated for a long-lasting rust-resistant, 
quality appearance.

 

Unit Design

 

 — All units are equipped 

with totally enclosed fan motors for 
greater reliability under rain and snow 

conditions. The large, wraparound coil 
uses copper tube and enhanced 
aluminum fin and is designed for 
optimum heat transfer during heating 
and cooling. The vertical air discharge 
carries the sound and air up and away 
from adjacent patio areas and foliage. 
Coils can be cleaned with a common 
garden hose.

 

External Service Valves

 

 — Both 

service valves are brass, front seating 
type. Valves are externally located 
so refrigerant tube connections can 
be made quickly and easily. Each 
valve has a service port for ease of 
checking operating refrigerant 
pressures. The 38YCB has sweat 
field connections. 

 

Safety

 

 — All units are designed and 

manufactured in accordance with 
Underwriters Laboratories (U.L. 1995) 
standard for safety, heating and 
cooling equipment.

 

Model number nomenclature

 

38YCB

036

Electric Heat Pump

Nominal Capacity

 

024 — 24,000 Btuh (7.0 Kw)

048 — 48,000 Btuh (14.1 Kw)

036 — 36,000 Btuh (10.6 Kw) 060 — 60,000 Btuh (17.6 Kw)

 

9

0

1

Packaging

Series

Electrical

 

7 — 240-1-50
9 — 400-3-50

 

Quality Assurance

 

Summary of Contents for 38YCB

Page 1: ...nd excess humidity during the cooling season FEATURES BENEFITS Electrical Range Units are offered in single phase 220 240v Three phase units are available in sizes 036 048 and 060 in 400v Size Range T...

Page 2: ...e A coat of modified polyester powder coating is then applied and baked on providing each unit with a hard smooth finish that will last for many years All screws on cabinet exterior are coated for a l...

Page 3: ...Copeland Recip Millennium Scroll Millennium Scroll REFRIGERANT Control Charge Lb Kg 15 ft 22 Piston 4 04 2 2 7 9 3 8 5 3 2 4 7 25 10 9 4 9 10 75 CONDENSER FAN Air Discharge Air Qty CFM L S Motor RPM 5...

Page 4: ...zes KSASH1101COP Sound Blanket Size 024 KSASH2001CYL Sound Blanket Sizes 036 70 90 048 060 KHAOT0301FST Outdoor Thermostat All Sizes KHAOT0201SEC Secondary Outdoor Thermostat All Sizes KHATX1001HSO TX...

Page 5: ...it when the heat pump switches to heating mode SUGGESTED USE All heat pumps where low ambient controller has been added 7 Liquid Solenoid Valve LSV An electrically operated shutoff valve to be install...

Page 6: ...75 C MAX LENGTH Ft 60 C 75 C MAX LENGTH m 60 C 75 C MAX FUSE OR HACR TYPE CKT BKR AMPS Max Min LRA RLA 024 70 230 1 253 207 68 0 11 5 1 4 15 8 14 14 55 39 16 7 11 9 25 036 70 94 0 16 5 1 4 22 2 12 12...

Page 7: ...2 70 5 91 5 91 2 81 5 65 5 65 2 92 5 39 5 39 3 03 5 13 5 13 3 13 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity...

Page 8: ...11 5 6 04 11 1 11 1 6 40 14 13 5 13 5 4 45 13 1 13 1 4 73 12 8 12 8 5 03 12 4 12 4 5 34 11 9 11 9 5 68 11 5 11 5 6 04 11 1 11 1 6 40 Multipliers for Determining the Performance With Other Indoor Secti...

Page 9: ...3 21 3 2 68 20 1 20 1 2 83 18 9 18 9 2 99 17 6 17 6 3 13 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power...

Page 10: ...39 7 33 7 6 47 62 47 8 46 6 4 19 45 8 45 4 4 55 43 9 43 9 4 95 41 9 41 9 5 39 40 0 40 0 5 86 38 0 38 0 6 37 57 47 4 47 4 4 18 45 7 45 7 4 55 43 8 43 8 4 95 42 0 42 0 5 39 40 0 40 0 5 86 38 0 38 0 6 3...

Page 11: ...3 73 1 78 5 26 4 73 2 09 5 91 5 51 2 26 6 61 6 58 2 44 7 41 7 41 2 66 8 26 8 26 2 89 9 14 9 14 3 15 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Heating I...

Page 12: ...r Determining the Performance With Other Indoor Sections Indoor Section Size Heating Indoor Section Size Heating Capacity Power Capacity Power F A B 4AS F B 048 1 00 1 00 FG3ASA 048 1 00 1 03 060 0 99...

Page 13: ...1 57 13 8 12 6 1 77 16 5 14 6 1 98 19 5 17 7 2 20 22 8 22 8 2 46 26 6 26 6 2 76 30 8 30 8 3 11 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Heating Indoo...

Page 14: ...40 3 36 6 3 91 47 8 47 8 4 11 56 7 56 7 4 34 67 3 67 3 4 64 70 1400 18 5 17 1 3 41 23 0 21 1 3 54 27 7 25 3 3 70 33 1 29 4 3 87 39 3 35 7 4 07 46 4 46 4 4 29 55 3 55 3 4 59 65 3 65 3 4 93 1600 18 8 1...

Page 15: ...6 In 152 4mm on one side 12 In 304 8mm on remaining side and 24 In 609 6mm between units for proper airflow 2 Minimum outdoor operating ambient in cooling mode is 55 F 13 C max 125 F 52 C 3 Maximum ou...

Page 16: ...NG HEAT LOSS KW UNIT INTEGRATED HEATING CAPACITY KW Printed in U S A 11 94 OUTDOOR TEMPERATURE C 20 10 0 10 20 30 20 10 40 BASED ON INDOOR ENT AIR AT 21 C AND AT RATED CFM 38YCB024 FB4AS024 38YCB036 F...

Page 17: ...T INTEGRATED HEATING CAPACITY 1000 BTU HR Printed in U S A 11 94 OUTDOOR TEMPERATURE F 10 0 10 20 30 40 50 60 70 80 70 60 50 40 30 20 10 80 38YCB024 FB4AS024 38YCB036 FB4AS036 38YCB048 FB4AS048 38YCB0...

Page 18: ...Condenser fan will be direct drive propeller type discharging air upward Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts...

Page 19: ...19...

Page 20: ...Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Page 20 Catalog No 013 881 Printed in U S A PC...

Reviews: