Carrier 38YCB Product Data Download Page 15

15

Certified drawing—38YCB

A96221

AIR DISCHARGE

AIR IN

A

 

SQ

B

P

C

3

/

IN.

 (9.5mm) DIA

TIEDOWN

KNOCKOUTS

(2) PLACES IN

BASEPAN

2

 

7

/

8

(73.0mm)

1

 1

/

4

(31.8mm)

H

G

F

E

FIELD CONTROL SUPPLY 
CONN  

7

/

IN. 

(22.2mm) DIA 

HOLE

FIELD POWER SUPPLY CONN

7

/

IN.

 

(22.2mm) DIA HOLE WITH 

1

/

IN. 

(

28.6mm

DIA KNOCKOUT 

AND 1 

3

/

IN. 

(34.9mm) DIA 

KNOCKOUT
 

3

/

IN. 

(9.5mm) DIA LIQUID 

LINE CONN

DIA SERVICE LINE CONN

L

K

J

AIR IN

M

N

AIR DISCHARGE

AIR IN

AIR IN

38YCB024

38YCB036

38YCB036

38YCB048

38YCB048

38YCB048

38YCB060

38YCB060

0

0

1

0

1

2

0

2

460.4

596.9

596.9

596.9

596.9

596.9

596.9

596.9

571.5

762.0

762.0

762.0

762.0

762.0

762.0

762.0

862.0

1014.4

1014.4

862.0

862.0

862.0

862.0

862.0

81.0

82.6

82.6

82.6

82.6

82.6

82.6

82.6

15.9

19.1

19.1

22.2

22.2

22.2

22.2

22.2

501.7

692.2

692.2

692.2

692.2

692.2

692.2

692.2

549.3

739.8

739.8

739.8

739.8

739.8

739.8

739.8

365.1

508.0

508.0

508.0

508.0

508.0

508.0

508.0

479.4

669.9

669.9

669.9

669.9

669.9

669.9

669.9

560.4

750.9

750.9

750.9

750.9

750.9

750.9

750.9

304.8

400.1

400.1

400.1

400.1

396.9

396.9

400.1

317.5

381.0

381.0

381.0

381.0

387.4

400.1

396.9

355.6

393.7

393.7

393.7

393.7

393.7

381.0

384.2

65.9

100.9

100.0

100.0

104.1

105.0

118.6

120.0

UNIT

SERIES

ELECTRICAL

CHARACTERISTICS

A

B

C

D

93.6

165.1

165.1

165.1

165.1

165.1

165.1

165.1

E

F

G

H

J

K

L

 

N

P

SHIPPING

WEIGHT

X = YES
O = NO

X = YES
O = NO

1.  Allow 30 In. 

(

762.0mm

clearance to service side of

     unit, 48 In. 

(

1219.2mm

above unit, 6 In. (152.4mm) on one side, 12 In.(304.8mm)

     on remaining side, and 24 In. 

(

609.6mm

between

     units for proper airflow.
2.  Minimum outdoor operating ambient in cooling mode is
     55

°

F(13

°

C), max 125

°

F(52

°

C).

3.  Maximum outdoor operating ambient in the heating mode is 66

°

F(19

°

C).

4.  Series designation is the 13th position of the unit
     model number.
5.  Center of gravity    .

NOTES:

024

36

48, 60

22 

1

2

 

x 22 

1

2

30

 

x 30

571.5 x 571.5

762.0 x 762.0

UNIT SIZE

MINIMUM

MOUNTING PAD

DIMENSIONS (In.)

MINIMUM

MOUNTING PAD

DIMENSIONS (mm)

AIR DISCHARGE

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

kg

38YCB024

38YCB036

38YCB036

38YCB048

38YCB048

38YCB048

38YCB060

38YCB060

0

0

1

0

1

2

0

2

18 

1

8

23 

1

2

23 

1

2

23 

1

2

23 

1

2

23 

1

2

23 

1

2

23 

1

2

22 

1

2

30

30

30

30

30

30

30

33 

15

16

39 

15

16

39 

15

16

33 

15

16

33 

15

16

33 

15

16

33 

15

16

33 

15

16

5

8

 

3

4

3

4

7

8

7

8

7

8

7

8

7

8

3

16

1

4

1

4

1

4

1

4

1

4

1

4

1

4

19 

3

4

27 

1

4

27 

1

4

27 

1

4

27 

1

4

27 

1

4

27 

1

4

27 

1

4

21 

5

8

29 

1

8

29 

1

8

29 

1

8

29 

1

8

29 

1

8

29 

1

8

29 

1

8

14 

3

8

20

20

20

20

20

20

20

18 

7

8

26 

3

8

26 

3

8

26 

3

8

26 

3

8

26 

3

8

 26 

3

8

 26 

3

8

 

 

22 

1

16

29 

9

16

29 

9

16

29 

9

16

29 

9

16

29 

9

16

 

29 

9

16

29 

9

16

12 

1

2

15

15

15

15

 

15 

1

4

15 

3

4

15 

5

8

12

15 

3

4

15 

3

4

15 

3

4

15 

3

4

 

15 

5

8

15 

5

8

15 

3

4

 

14

15 

1

2

15 

1

2

15 

1

2

15 

1

2

 

15 

1

2

 

15

15 

1

8

 

145

222

220

220

229

231

261

264

UNIT

SERIES

ELECTRICAL

CHARACTERISTICS

A

B

C

D

11

16

1

2

1

2

1

2

1

2

1

2

1

2

1

2

E

F

G

H

J

K

L

 

N

P

SHIPPING

WEIGHT

In.

In.

In.

In.

In.

In.

In.

In.

In.

In.

In.

In.

In.

In.

Lb.

S.I.

ENGLISH

X

X

X

X

O

O

O

O

O

X

X

X

X

X

X

X

230-1-50

400-3-50

X

X

X

X

O

O

O

O

O

X

X

X

X

X

X

X

230-1-50

400-3-50

Summary of Contents for 38YCB

Page 1: ...nd excess humidity during the cooling season FEATURES BENEFITS Electrical Range Units are offered in single phase 220 240v Three phase units are available in sizes 036 048 and 060 in 400v Size Range T...

Page 2: ...e A coat of modified polyester powder coating is then applied and baked on providing each unit with a hard smooth finish that will last for many years All screws on cabinet exterior are coated for a l...

Page 3: ...Copeland Recip Millennium Scroll Millennium Scroll REFRIGERANT Control Charge Lb Kg 15 ft 22 Piston 4 04 2 2 7 9 3 8 5 3 2 4 7 25 10 9 4 9 10 75 CONDENSER FAN Air Discharge Air Qty CFM L S Motor RPM 5...

Page 4: ...zes KSASH1101COP Sound Blanket Size 024 KSASH2001CYL Sound Blanket Sizes 036 70 90 048 060 KHAOT0301FST Outdoor Thermostat All Sizes KHAOT0201SEC Secondary Outdoor Thermostat All Sizes KHATX1001HSO TX...

Page 5: ...it when the heat pump switches to heating mode SUGGESTED USE All heat pumps where low ambient controller has been added 7 Liquid Solenoid Valve LSV An electrically operated shutoff valve to be install...

Page 6: ...75 C MAX LENGTH Ft 60 C 75 C MAX LENGTH m 60 C 75 C MAX FUSE OR HACR TYPE CKT BKR AMPS Max Min LRA RLA 024 70 230 1 253 207 68 0 11 5 1 4 15 8 14 14 55 39 16 7 11 9 25 036 70 94 0 16 5 1 4 22 2 12 12...

Page 7: ...2 70 5 91 5 91 2 81 5 65 5 65 2 92 5 39 5 39 3 03 5 13 5 13 3 13 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity...

Page 8: ...11 5 6 04 11 1 11 1 6 40 14 13 5 13 5 4 45 13 1 13 1 4 73 12 8 12 8 5 03 12 4 12 4 5 34 11 9 11 9 5 68 11 5 11 5 6 04 11 1 11 1 6 40 Multipliers for Determining the Performance With Other Indoor Secti...

Page 9: ...3 21 3 2 68 20 1 20 1 2 83 18 9 18 9 2 99 17 6 17 6 3 13 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power...

Page 10: ...39 7 33 7 6 47 62 47 8 46 6 4 19 45 8 45 4 4 55 43 9 43 9 4 95 41 9 41 9 5 39 40 0 40 0 5 86 38 0 38 0 6 37 57 47 4 47 4 4 18 45 7 45 7 4 55 43 8 43 8 4 95 42 0 42 0 5 39 40 0 40 0 5 86 38 0 38 0 6 3...

Page 11: ...3 73 1 78 5 26 4 73 2 09 5 91 5 51 2 26 6 61 6 58 2 44 7 41 7 41 2 66 8 26 8 26 2 89 9 14 9 14 3 15 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Heating I...

Page 12: ...r Determining the Performance With Other Indoor Sections Indoor Section Size Heating Indoor Section Size Heating Capacity Power Capacity Power F A B 4AS F B 048 1 00 1 00 FG3ASA 048 1 00 1 03 060 0 99...

Page 13: ...1 57 13 8 12 6 1 77 16 5 14 6 1 98 19 5 17 7 2 20 22 8 22 8 2 46 26 6 26 6 2 76 30 8 30 8 3 11 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Heating Indoo...

Page 14: ...40 3 36 6 3 91 47 8 47 8 4 11 56 7 56 7 4 34 67 3 67 3 4 64 70 1400 18 5 17 1 3 41 23 0 21 1 3 54 27 7 25 3 3 70 33 1 29 4 3 87 39 3 35 7 4 07 46 4 46 4 4 29 55 3 55 3 4 59 65 3 65 3 4 93 1600 18 8 1...

Page 15: ...6 In 152 4mm on one side 12 In 304 8mm on remaining side and 24 In 609 6mm between units for proper airflow 2 Minimum outdoor operating ambient in cooling mode is 55 F 13 C max 125 F 52 C 3 Maximum ou...

Page 16: ...NG HEAT LOSS KW UNIT INTEGRATED HEATING CAPACITY KW Printed in U S A 11 94 OUTDOOR TEMPERATURE C 20 10 0 10 20 30 20 10 40 BASED ON INDOOR ENT AIR AT 21 C AND AT RATED CFM 38YCB024 FB4AS024 38YCB036 F...