![CARLO GAVAZZI LD30 BI10BP IO Series Manual Download Page 31](http://html1.mh-extra.com/html/carlo-gavazzi/ld30-bi10bp-io-series/ld30-bi10bp-io-series_manual_2558585031.webp)
Rev.00 - 01.2020 | LD30 IO-Link manual ENG | © 2020 |
CARLO GAVAZZI Industri
31
EN
7.2.4. Sensor specific adjustable parameters
Parameter Name
Index Dec
(Hex)
Access
Default value
Data range
Data Type
Length
Selection of local/remote
adjustment
68 (0x44)
R/W
1 = Trimmer input
0 = Disabled
1 = Trimmer input
2 = Teach-by-wire
UintegerT
8 bit
Trimmer value
69 (0x45)
RO
-
30 ... 1 100
-
-
Process data configuration
70 (0x46)
R/W
-
-
RecordT
16 bit
Analogue value
1 (0x01)
R/W
1 = Analogue value Active
0 = Analogue value Inactive
1 = Analogue value Active
-
-
Switching Output 1
2(0x02)
R/W
1 = Switching Output 1 Active
0 = Switching Output 1 Inactive
1 = Switching Output 1 Active
-
-
Switching Output 2
3 (0x03)
R/W
1 = Switching Output 2 Active
0 = Switching Output 2 Inactive
1 = Switching Output 2 Active
-
-
Switching Signal Channel 1
4 (0x04)
R/W
0 = SSC1 Inactive
0 = SSC1 Inactive
1 = SSC1 Active
-
-
Switching Signal Channel 2
5 (0x05)
R/W
0 = SSC2 Inactive
0 = SSC2 Inactive
1 = SSC2 Active
-
-
Temperature alarm
6 (0x06)
R/W
0 = TA Inactive
0 = TA Inactive
1 = TA Active
-
-
Short-circuit
7 (0x07)
R/W
0 = SC Inactive
0 = SC Inactive
1 = SC Active
-
-
Sensor Application pre-set
71 (0x47)
R/W
0 = Normal
0 = Normal/defeat precision (fast)
1 = High precision (slow)
2 = Customized (filter scaler)
UintegerT
8 bit
Temperature Alarm Threshold
72 (0x48)
R/W
-
-
RecordT
30 bit
High Threshold
1 (0x01)
R/W
70°C
-30 ... 70°C
IntegerT
16 bit
Low Threshold
2 (0x02)
R/W
-20°C
-30 ... 70°C
IntegerT
16 bit
Event Configuration
74 (0x4A)
R/W
-
-
RecordT
16 bit
Temperature fault event
(0x4000)
1 (0x01)
R/W
0 = Temperature fault
Error event - Inactive
0 = Error event Inactive
1 = Error event Active
-
-
Temperature over-run
(0x4210)
2 (0x02)
R/W
0 = Temperature over-run
Warning event - Inactive
0 = Warning event Inactive
1 = Warning event Active
-
-
Temperature under-run
(0x4220)
3 (0x03)
R/W
0 = Temperature under-run
Warning event - Inactive
0 = Warning event Inactive
1 = Warning event Active
-
-
Short circuit (0x7710)
4 (0x04)
R/W
0 = Short circuit
Error event - Inactive
0 = Error event Inactive
1 = Error event Active
-
-
Quality of Teach
75 (0x4B)
RO
-
0…100
UintegerT
8 bit
Quality of Run
76 (0x4C)
RO
-
0…100
UintegerT
16 bit
Rating
1 (0x01)
RO
-
Sensor overall health check
[0-100] 100=best
-
-
SignalLow
2 (0x02)
RO
-
0 = Signal OK
1 = Signal low
-
-
AmbientHigh
3 (0x03)
RO
-
0 = ambient OK
1 = ambient high
-
-
NoObjectDetected
4 (0x04)
RO
-
0 = Object detected
1 = Object not detected
-
-
TemperatureError
5 (0x05)
RO
-
0 = Temperature OK
1 = Temperature outside min/max
limits
-
-
Filter scaler
77 (0x4D)
R/W
1
1…255
UintegerT
8 bit
LED indication
78 (0x4E)
R/W
1 = LED indication Active
0 = LED indication Inactive
1 = LED indication Active
2 = Find my sensor
UintegerT
8 bit
CutOffDistance
79 (0x4F)
R/W
1500
0 ... 2000
Uinteger
16 bit