![CARLO GAVAZZI LD30 BI10BP IO Series Manual Download Page 16](http://html1.mh-extra.com/html/carlo-gavazzi/ld30-bi10bp-io-series/ld30-bi10bp-io-series_manual_2558585016.webp)
Rev.00 - 01.2020 | LD30 IO-Link manual ENG | © 2020 |
CARLO GAVAZZI Industri
16
EN
2.4.4.1.5. One shot leading edge
Each time a target is detected in front of the sensor the switching output generates a pulse of constant
length on the leading edge of the detection. This function is not retriggerable. See figure below.
N.O.
∆t
∆t
∆t
∆t
Presence of target
2.4.4.1.6. One shot trailing edge
Similar in function to the one shot leading edge mode, but in this mode the switching output is changed on
the trailing edge of the activation as shown in the figure below. This function is not retriggerable.
Example with normally open output
N.O.
∆t
∆t
∆t
∆t
Presence of target
Example with normally open output
2.4.4.2. Timer scale
The parameter defines if the delay specified in the Timer delay should be in milliseconds, seconds or minutes
2.4.4.3. Timer Value
The parameter defines the actual duration of the delay. The delay can be set to any integer value between
1 and 32 767.