26
© Carlo Gavazzi A/S
Installation of the Standard Spot Detection System
Short Installation
The idea of this short installation section is to give the installer a tool to cover most questions when
making the installation of cables, sensors etc� Now the planning has ended, and we move forward
towards the installation process starting with:
Sensors
•
Pre-program the sensors before mounting in the ceiling� See Programming section below�
•
Sensors must be installed at a distance of minimum 1�5 m(4�95 feet) and maximum 4�0
m(13�2 feet) from the floor�
•
Use e�g� cable trays to mount the sensors and save labour costs�
•
Sensors must be mounted in the middle of the Parking Guidance System space directly
over the car�
•
For aesthetic reasons, it is best to mount the sensors in a straight line amd at the same
height over each Parking Guidance System space�
•
Mount sensors so that they point directly down to the ground with a maximum angle of 5
degrees�
•
When mounting the wires into the push wire connectors on the sensors and the LED indica-
tors:
•
cut the isolation carefully so the conductor is not damaged�
•
cut only 1 cm (�394 or 25/64 inches) of the inner isolation on the conductor that is to
be pressed in the push wire connector� See "General Installation" below for a more
firm description�
•
If using the new 3-colour sensor, the same precautions as with the 2-coloured sensor should
be taken�
LED Indicators
•
When using indicators separate from the sensors for maximum viewing, the LED indicators
should be installed outside the Parking Guidance System place in the drive lane�
•
It should be mounted in the ceiling, in an aesthetic straight line and in the same height over
the floor�
•
If using the new 3-colour Dupline Bus powered LED indicator, the same precautions should
be taken as for the 2-coloured LED indicator� However, this new type must be connected to
the Dupline L1 bus (same L1 bus as the sensors)�
Car Park Monitor (CPM) Modules
The CPM modules have three different functions (modes)� They can be slaves, master indicator or
master CPM�
Slaves
•
Connect the L1 bus on the CPM module to the sensors� Each slave is a segment� Use 1�5
mm
2
(14-16AWG) wire�