Car Park 3
–
Planning and design
12
4. Addressing parking bays and displays
You can address the parking bays and the displays using the UWP 3.0 Tool.
Notes
•
All the sensor bases have a unique SIN number. The SIN numbers do not need to be in
consecutive order, but their activation does.
•
You can use the same sensor for different purposes (Normal, Disabled, VIP) one next to
the other: the difference is generated by the UWP 3.0 Tool.
5. Designing the placement of the master channel generator
It is very important to define the sensors mounting place for wiring them according to the master
channel generators position.
Rule of thumb
•
A maximum of 50 sensors in a line
•
A maximum of 90 sensors per generator
•
A maximum of 150 m (490 feet) of wire in a line (branch)
Notes:
•
The wire must be an unshielded 14-16 AWG type (1.5mm