SPX II Series
Options
03.17
Operating Manual
59
Press key
to arrive the next parameter.
The label transfer from print module to applicator is controlled by a
vacuum sensor. If the transfer of label fails, the sucking holes on the
pad will not be covered by the label and therefore no vacuum can
originate on the pad. Afterwards an error message appears and the
label strip will be fed back.
If the parameter 'vacuum control' is set to Off, the error treatment as
described above will not be effected. This can be especially helpful
during adjustments, because the immediate backfeed will be
cancelled and therefore it is easier to check the reasons for the faulty
transfer.
For standard operation, set the parameter to On.
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'stamp on' is
selected. The time period can be adjusted while the stamp is kept in
the labelling position for applying the label onto the goods.
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'blow on' is
selected. The time period can be adjusted, while the blowing air is
switched on for transferring the label onto product.
Value range: 0
… 2500 ms
Step size: 10 ms
Default: 100 ms
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'blow on' and
mode 'apply-print' are selected.
Waiting position up:
In cyclic mode the pad with the printed label waits in the labelling
position near the dispense edge of print module for the external start
signal.
Waiting position down:
In cyclic mode the printed label is transported to the labelling position
at the end of a cycle.
So the next cycle begin with blowing up the label.
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'blow on' is
selected. The time period can be adjusted while the roll on pad is
stopped in labelling position.
Value range: 0
… 5000 ms
Step size: 10 ms
Default: 0 ms
Press key
to arrive the next parameter.
This parameter is only active if the operating mode 'blow on' and 'roll
on' are selected. The time period can be adjusted for the cleaning
period of pad after application procedure.
Value range: 0
… 2500 ms
Step size: 10 ms
Default: 100 ms
Vacuum control
Pressure time
Blow time
Waiting position
Roll on time
Cleaning time