Spectra II Serie
Maintenance and Cleaning
10.16
Operating Manual
47
7
Maintenance and Cleaning
DANGER!
Risk of death by electric shock!
Disconnect the label printer from power supply
before performing any maintenance work.
NOTICE!
When cleaning the label printer, personal protective equipment
such as safety goggles and gloves are recommended.
Maintenance task
Frequency
General cleaning (see chapter
7.1, page 48).
As necessary.
Cleaning transfer ribbon
drawing roller (see section 7.2,
page 48).
Each time the transfer ribbon is
changed or when the printout is
adversely affected.
Cleaning pressure roller (see
chapter 7.1, page 48).
Each time the label roll is
changed or when the printout and
label transport are adversely
affected.
Cleaning printhead (see chapter
7.4, page 50).
Each time the transfer ribbon is
changed or when the printout is
adversely affected.
Cleaning label photocell (see
chapter 7.5, page 51).
When exchanging the label roll.
Replacing printhead (see
chapter 7.6, page 52).
When errors in the printout occur.
NOTICE!
The handling instructions for the use of Isopropanol (IPA) must
be observed. In the case of skin or eye contact, immediately
wash off the fluid thoroughly with running water. If the irritation
persists, consult a doctor. Ensure good ventilation.
Maintenance schedule