4.3 Parameter tables
The following tables show of the parameters divided by type/family (e. g. compressor, probes,
fans etc.).
• Key to the parameter tables
Level
(default)
S= super user
F= factory
D= direct
Visibility:
The visibility of some groups depends on the type of controller and the value of the parameters.
D= defrost (if D01=1)
F= fan (if F01=1)
L= low noise (if F15=1-3)
N= NTC probe (if /04-/08=2)
P= pressure (if /04-/08=3)
V= driver (if H08 =1, 3, 4)
X= expansion (if H08=2, 3, 4)
M= pump down (if D17=1)
W= watch (if the clock board is fi tted)
- = always present
Supervisor variables:
R/W = supervisor read/write parameter
R= supervisor read-only parameter
4.3.1 Evaporator and condenser temperature and pressure values: (d*)
display
indicat.
parameter and description
default
level
min.
max.
UOM variat. default visibility
supervis.
variable
Modbus
variable
type
dtE
Current value of DTE
D
0
0
-
-
0
-
99 (R)
99
Analog
dC1
Current value of DTC1
D
0
0
-
-
0
-
100 (R)
100
Analog
dC2
Current value of DTC2
D
0
0
-
-
0
-
101 (R)
101
Analog
Tab. 4.a
4.3.2 Probe setting parameters: (/*)
display
indicat.
parameter and description
default
level
min. max. UOM
variat.
default visibility supervis.
variable
Modbus variable
type
/01
Probe type B1
0= not present
1= present
F
0
1
Flag
1
1
-
1 (R/W)
1
Digital
/02
Probe type B2
0= not present
1= present
F
0
1
Flag
1
0
-
2 (R/W)
2
Digital
/03
Probe type B3
0= not present
1= NTC Cond. Probe
2= NTC Out. Probe
3= diff erential control probe
F
0
3
int
1
0
-
14 (R/W)
221
Integer
/04
Probe type B4
0= not present
1= ON/OFF (D.I)
2= NTC Out. Probe
3= ratiometric cond. Probe, 5 Vdc
4= diff erential control probe
F
0
4
int
1
0
-
15 (R/W)
222
Integer
/05
Probe type B5
0= not present
1= present
F
0
1
Flag
1
0
X
3 (R/W)
3
Digital
/06
Probe type B6
0= not present
1= present
F
0
1
Flag
1
0
X
4 (R/W)
4
Digital
/07
Probe type B7
0= not present
1= NTC Cond. Probe
2= NTC Out. Probe
3= diff erential control probe
F
0
2
int
1
0
X
16 (R/W)
223
Integer
/08
Probe type B8
(expansion)
0= not present
1= ON/OFF
2= NTC Out. Probe
3= ratiometric cond. Probe, 5 Vdc
4= diff erential control probe
NB. if more than one diff erential control
probe is confi gured, the priority is: B8, B7,
B4, B3
F
0
3
int
1
0
X
17 (R/W)
224
Integer
/09
Min. value voltage input
F
0
/10
0.01 Vdc 1
50
P
18 (R/W)
225
Integer
/10
Max. value voltage input
F
/09
500
0.01 Vdc 1
450
P
19 (R/W)
226
Integer
/11
Pressure min. value
F
0
/12
bar
1
0
P
1 (R/W)
1
Analog
/12
Pressure max. value
F
/11
99.9
bar
1
34.5
P
2 (R/W)
2
Analog
/13
Probe B1 calibration
F
-12.0 12.0
°C/°F
0.1
0.0
-
3 (R/W)
3
Analog
/14
Probe B2 calibration
F
-12.0 12.0
°C/°F
0.1
0.0
-
4 (R/W)
4
Analog
/15
Probe B3 calibration
F
-12.0 12.0
°C/°F
0.1
0.0
-
5 (R/W)
5
Analog
/16
Probe B4 calibration
F
-12.0 12.0
°C/bar/°F 0.1
0.0
-
6 (R/W)
6
Analog
/17
Probe B5 calibration
F
-12.0 12.0
°C/°F
0.1
0.0
X
7 (R/W)
7
Analog
/18
Probe B6 calibration
F
-12.0 12.0
°C/°F
0.1
0.0
X
8 (R/W)
8
Analog
/19
Probe B7 calibration
F
-12.0 12.0
°C/°F
0.1
0.0
X
9 (R/W)
9
Analog
/20
Probe B8 calibration
F
-12.0 12.0
°C/bar/°F 0.1
0.0
X
10 (R/W)
10
Analog
/21
Digital fi lter
U
1
15
-
1
4
-
20 (R/W)
227
Integer
/22
Input limitation
U
1
15
-
1
8
-
21 (R/W)
228
Integer
/23
Unit of measure
0= °C
1= °F
U
0
1
Flag
1
0
-
5 (R/W)
5
Digital
Table. 4.b
Summary of Contents for uC2SE
Page 1: ...C2 SE electronic control User manual...
Page 2: ......
Page 4: ...4 E N G L I S H C2 SE 030220426 rel 2 1 09 06 2010...
Page 6: ...6 E N G L I S H C2 SE 030220426 rel 2 1 09 06 2010...
Page 72: ...72 E N G L I S H C2 SE 030220426 rel 2 1 09 06 2010...
Page 73: ...73 E N G L I S H C2 SE 030220426 rel 2 1 09 06 2010...
Page 74: ...74 E N G L I S H C2 SE 030220426 rel 2 1 09 06 2010...
Page 75: ......