27
ENG
c.pCO sis
tem
a
+
0300057EN
re
l. 1.2 - 29.05.2017
Ref. Term.
Label
Description
8
J5-1
ID1
Digital input 1 at voltage A(*)
J5-2
ID2
Digital input 2 at voltage A(*)
J5-3
ID3
Digital input 3 at voltage A(*)
J5-4
ID4
Digital input 4 at voltage A(*)
J5-5
ID5
Digital input 5 at voltage A(*)
J5-6
ID6
Digital input 6 at voltage A(*)
J5-7
ID7
Digital input 7 at voltage A(*)
J5-8
ID8
Digital input 8 at voltage A(*)
J5-9
IDC1
Common for digital inputs from 1 to 8 (negative
pole for DC power supply)
8
J7-1
ID9
Digital input 9 at voltage A(*)
J7-2
ID10
Digital input 10 at voltage A(*)
J7-3
ID11
Digital input 11 at voltage A(*)
J7-4
ID12
Digital input 12 at voltage A(*)
J7-5
IDC9
Common for digital inputs from 9 to 12 (negative
pole for DC power supply
8
J20-7
i
ID17
Digital input 17 at voltage A(*)
J20-8
i
ID18
Digital input 18 at voltage A(*)
J20-9
i
IDC17
Common for digital inputs 17 and 18 (negative
pole for DC power supply
9
J8-1
ID13H
Digital input 13 at voltage B(**)
J8-2
ID13
Digital input 13 at voltage A(*)
J8-3
IDC13
Common for digital inputs 13 and 14 (negative
pole for DC power supply)
J8-4
ID14
Digital input 14 at voltage A(*)
J8-5
ID14H
Digital input 14 at voltage B(**)
9
J19-1
i
ID15H
Digital input 15 at voltage B(**)
J19-2
i
ID15
Digital input 15 at voltage A(*)
J19-3
i
IDC15
Common for digital inputs 15 and 16 (negative
pole for DC power supply)
J19-4
i
ID16
Digital input 16 at voltage A(*)
J19-5
i
ID16H
Digital input 16 at voltage B(**)
10
J10
-
Connector for telephone cable pLAN
11
J11-1
Tx-/Rx-
pLAN RS485 port Tx-/Rx-
J11-2
Tx+/Rx+ pLAN RS485 port Tx+/Rx+
J11-3
GND
pLAN RS485 port GND
12
-
-
Reserved
13
-
-
Ethernet port 1
14
-
-
Ethernet port 2
15
J12-1
C1
Common for relays 1, 2, 3
J12-2
NO1
Normally open contact, relay 1
J12-3
NO2
Normally open contact, relay 2
J12-4
NO3
Normally open contact, relay 3
J12-5
C1
Common for relay 1, 2, 3
J13-1
C4
Common for relay 4, 5, 6
J13-2
NO4
Normally open contact, relay 4
J13-3
NO5
Normally open contact, relay 5
J13-4
NO6
Normally open contact, relay 6
J13-5
C4
Common for relay 4, 5, 6
J14-1
C7
Common for relay 7
J14-2
NO7
Normally open contact, relay 7
J14-3
C7
Common for relay 7
J15-1
NO8
Normally open contact, relay 8
J15-2
C8
Common for relay 8
J15-3
NC8
Normally closed contact 8
J16-1
C9
Common for relay 9, 10, 11
J16-2
NO9
Normally open contact, relay 9
J16-3
NO10
Normally open contact, relay 10
J16-4
NO11
Normally open contact, relay 11
J16-5
C9
Common for relay 9, 10, 11
J17-1
NO12
Normally open contact, relay 12
J17-2
C12
Common for relay 12
J17-3
NC12
Normally closed contact 12
J18-1
NO13
Normally open contact, relay 13
J18-2
C13
Common for relay 13
J18-3
NC13
Normally closed contact 13
J21-1
i
NO14
Normally open contact, relay 14
J21-2
i
C14
Common for relay 14
J21-3
i
NC14
Normally closed contact 14
J21-4
i
NO15
Normally open contact, relay 15
J21-5
i
C15
Common for relay 15
J21-6
i
NC15
Normally closed contact 15
J22-1
i
C16
Common for relay 16, 17, 18
J22-2
i
NO16
Normally open contact, relay 16
J22-3
i
NO17
Normally open contact, relay 17
J22-4
i
NO18
Normally closed contact 18
J22-5
i
C16
Common for relay 16, 17, 18
J21-1
ii
C14
Common for relay 14, 15, 16
J21-2
ii
NO14
Normally open contact, relay 14
J21-3
ii
NO15
Normally open contact, relay 15
J21-4
ii
NO16
Normally open contact, relay 16
J21-5
ii
C14
Common for relay 14, 15, 16
Ref. Term.
Label
Description
15
J22-1
ii
C17
Common for relay 17, 18, 19, 20
J22-2
ii
NO17
Normally open contact, relay 17
J22-3
ii
NO18
Normally open contact, relay 18
J22-4
ii
NO19
Normally open contact, relay 19
J22-5
ii
NO20
Normally open contact, relay 20
J22-6
ii
C17
Common for relay 17, 18, 19, 20
J19-1
ii
C21
Common for relay 21, 22, 23, 24
J19-2
ii
NO21
Normally open contact, relay 21
J19-3
ii
NO22
Normally open contact, relay 22
J19-4
ii
NO23
Normally open contact, relay 23
J19-5
ii
NO24
Normally open contact, relay 24
J19-6
ii
C21
Common for relay 21, 22, 23, 24
J20-1
ii
C25
Common for relay 25, 26, 27, 28, 29
J20-2
ii
NO25
Normally open contact, relay 25
J20-3
ii
NO26
Normally open contact, relay 26
J20-4
ii
NO27
Normally open contact, relay 27
J20-5
ii
NO28
Normally open contact, relay 28
J20-6
ii
NO29
Normally open contact, relay 29
J20-7
ii
C25
Common for relay 25, 26, 27, 28, 29
16
J25-1
Tx-/Rx-
Tx-/Rx- RS485 BMS2 port
J25-2
Tx+/Rx+ Tx+/Rx+ RS485 BMS2 port
J25-3
GND
GND RS485 BMS2 port
17
J26-1
Tx-/Rx-
Tx-/Rx- RS485 Fieldbus 2 port
J26-2
Tx+/Rx+ Tx+/Rx+ RS485 Fieldbus 2 port
18
Port J26 configuration microswitches
19
J23-1
Tx-/Rx-
Tx-/Rx- Fieldbus 2 RS485 port
J23-2
Tx+/Rx+ Tx+/Rx+ Fieldbus 2 RS485 port
J23-3
GND
GND RS485 port network Fieldbus 2
For pCO5+ built-in driver only:
20
J27-1
1
Electronic expansion valve 1 control (see par.
“Electronic valve connection”).
J27-2
3
J27-3
2
J27-4
4
21
J28-1
1
Electronic expansion valve 2 control (see par.
“Electronic valve connection”).
J28-2
3
J28-3
2
J28-4
4
22
J30-1
VBAT
Power supply from external Ultracap module
J30-2
G0
J30-3
G
23
J29-1
GND
Common probe power supply
J29-2
VREF
Probe driver power supply
J29-3
S1
Probe 1
J29-4
S2
Probe 2
J29-5
S3
Probe 3
J29-6
S4
Probe 4
J29-7
DI1
Digital input 1
J29-8
DI2
Digital input 2
24
A, B
Valve A status LED
C, D
Valve B status LED
Tab. 4.c
(*): voltage A: 24 Vac or 28...36 Vdc;
(**): voltage B: 230 Vac - 50/60 Hz.
i
: Large model;
ii
: Extralarge model