23
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
w
ith offset
no offset
19.2 K
9.6 K
38.4 K
57.6 K
CAREL
Modbus
ON
OFF
Addre
ss
E
xt.
Prot
B
a
ud
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
w
ith offset
no offset
19.2 K
9.6 K
38.4 K
57.6 K
CAREL
Modbus
ON
OFF
Addre
ss
E
xt.
Prot
B
a
ud
1
1
1
1
1
9
9
9
9
9
.
.
.
2
2
2
2
K
K
K
K
9
9
9
9
9
.
.
.6
6
6
6
6
K
K
K
K
K
K
3
3
3
3
3
8
8
8
8
8
.
.4
4
4
4
4
4
4
K
K
K
K
5
5
5
5
5
7
7
7
7
7
.
.6
6
6
6
6
6
6
K
K
K
K
C
C
C
CAREL
M
M
Modbus
P
P
P
P
r
ro
o
o
ot
t
t
t
B
a
a
a
a
a
a
u
u
u
u
u
u
d
d
d
d
d
d
d
d
ON
ON
F
ac
tory
s
ett
i
ng:
a
ddre
ss
= not
c
onfigured
exten
si
on = no off
s
et
B
a
ud R
a
te =
19
.
2
K
p
roto
c
o
l
= Modbu
s
Basic version
Addre
ss
E
xt B
a
ud Prot
15
10
1
2
3
6
8
ENG
c.pCO sis
tem
a
+
0300057EN
re
l. 1.2 - 29.05.2017
Fig. 4.t
D
escription of connection terminals on c.p
CO
mini/c.p
CO
e
See the figures on the previous pages relating to c.pCO mini/c.pCOe
Ref. Term.
Label
Description
1
J1-1
G
Power supply at voltage A(*)
J1-2
G0
Power supply reference
2
J1-3
Vbat
Power supply from external Ultracap module
3
J2-1
U1
Universal input/output 1
J2-2
U2
Universal input/output 2
J2-3
U3
Universal input/output 3
J2-4
GND
Common for universal inputs/outputs 1, 2, 3
J2-5
U4
Universal input/output 4
J2-6
U5
Universal input/output 5
J2-7
U6
Universal input/output 6
J2-8
GND
Common for universal inputs/outputs 4, 5, 6
J2-9
U7
Universal input/output 7
J2-10
U8
Universal input/output 8
J2-11
U9
Universal input/output 9
J2-12
U10
Universal input/output 10
J2-13
GND
Common for universal inputs/outputs 7, 8, 9, 10
4
J3-1
+Vterm Power supply for additional terminal
5
J3-2
Tx-/Rx-
Terminal RS485 port Tx-/Rx-
J3-3
Tx+/Rx+ Terminal RS485 port Tx+/Rx+
J3-4
GND
Terminal RS485 port GND
6
J10-1
NO1
Normally open contact, relay 1
J10-2
C1/2
Common for relay 1, 2
J10-3
NO2
Normally open contact, relay 2
J11-1
NO3
Normally open contact, relay 3
J11-2
C3/4/5
Common for relay 3, 4, 5
J11-3
NO4
Normally open contact, relay 4
J11-4
C3/4/5
Common for relay 3, 4, 5
J11-5
NO5
Normally open contact, relay 5
J12-1
NO6
Normally open contact, relay 6
J12-2
NC6
Normally closed contact, relay 6
J12-3
C6
Common for relay 6
7
J7
-
Single-pole valve connector
8
J9-1
+5 V
REF
Power supply ratiometric probes 0 to 5 V
J9-2
GND
Power supply common
J9-3
+VDC
Power to active probes
Ref. Term.
Label
Description
9
J4-1
Tx-/Rx-
FieldBus RS485 port Tx-/Rx-
J4-2
Tx+/Rx+ FieldBus RS485 port Tx+/Rx+
J4-3
GND
FieldBus RS485 port GND
10
J6-1
Tx-/Rx-
BMS RS485 port Tx-/Rx-
J6-2
Tx+/Rx+ BMS RS485 port Tx+/Rx+
J6-3
GND
BMS RS485 port GND
11
J8-4
Y1
Analogue output 1, 0...10 V
J8-5
Y2
Analogue output 2, 0...10 V
J8-6
GND
Common for analogue outputs 1, 2
12
J8-1
ID1
Digital input 1
J8-2
ID2
Digital input 2
J8-3
GND
Common for digital inputs 1, 2
13
J5-1
TxL/RxL CANbus port TxL/RxL
J5-2
TxH/RxH CANbus port TxH/RxH
J5-3
GND
CANbus port GND
(*) Voltage A: 24 Vac o 28...36 Vdc
c.p
CO
e -
D
I
N
rail version