9.PROBLEMS AND SOLUTIONS
9.1 Display doesn’t turn on
If turning on the machine the display doesn’t turn on, turn off the machine and wait for a minute before restarting. If
the display doesn’t turn on again, contact the constructor (See chapter 1 recapitulation machine marking data).
9.2 Console doesn’t turn on
Please check if the machine is correctly connected to power supply (See 3.7 electric requirements).
9.3 Touch screen doesn’t keep commands
Contact the constructor (See chapter 1 recapitulation machine marking data).
9.4 Shown calories are not correct
Please check if user’s personal data are correct or missing (See 5.7 personal data).
9.5 The running belt stops and restarts
Control the belt tension (see 3.11 best running belt tension) because if belt is too loose or too much lubricated it could
slip.
9.6 The running belt doesn’t keep center
The belt is too tight or user hangs on only one side handle. (See 3.10 how to center the running belt)
9.7 Inclination doesn’t work
Check the fuse (8A retard for M.D. range XR600 or 5A retard for M.D. range XR450) inside fuse box near the machine
power switch. If it’s o.k. contact the constructor (See chapter 1 recapitulation machine marking data).
9.8 The general electric power switch doesn’t stay on
Problems on inverter or motor in short circuit. Contact the constructor (See chapter 1 recapitulation machine marking
data).
9.9 Noise from motor
Contact the constructor (See chapter 1 recapitulation machine marking data).
9.10 Noise from roller
It is necessary to change the roller because of bearings seat ruined. Contact the constructor (See chapter 1 recapitulation
machine marking data).