background image

CARDIN 

ELETTRONICA 

spa 

Via Raffaello, 36- 31020 San Vendemiano (TV) Italy

Tel:  

+39/0438.404011-401818

Fax:  

+39/0438.401831

email (Italy): 

[email protected]

email (Europe): 

[email protected]

Http: 

www.cardin.it

S46

RXPR

06-07-2001

ZVL126.05

RADIOPROGRAmmER S46 WITH PROGRAmmABLE CODE

ELECTRICAL CONNECTION (fig. 3)

Before connecting the device to the mains make sure that:

-  the voltage and frequency rated on the data plate conform to those of the mains 

supply;

-  a bipolar circuit breaker which leaves at least 

3 mm between the contacts has been 

installed between the device and the mains;

-  the  high  voltage 

230V  wires  pass  through  the  holes  marked  "A"  and  are  routed 

separately from the low voltage wires which pass through the holes marked "

B"; 

-  the wires are fastened down using a cable clamp;

-  once the wiring is complete the holes through which the wires have passed have 

been sealed using silicon;

-  the holes which are not used are sealed by inserting the sealing caps "

D".

• Only low voltage circuits may be wired to the external circuit binding posts .

TERmINAL BOARD CONNECTIONS (fig. 3)

1-2  Earth connection

3-4  Radioprogrammer power supply 

230 Vac 50-60 Hz

5-6-7  Motor control in output  

350 W Close-Open-Neutral

8-9 

TD Dynamic button in input (contact N.O.)

10-11 

FTCII Contact N.C. in input for safety devices with travel direction inversion. 

Any eventual safety devices must be powered by an external power circuit

12  

Antenna braid

13 

Radio receiver antenna

Settings (fig. 3)

TL 

Work cycle regulation trimmer (3…120 sec.). The timer countdown starts after an 

opening or closing command has been received and stops after the programmed 

work time has elapsed.

PW  Power on LED.

STS   Lit: work cycle in course; flashing: photoelectric cell in alarm. 

TRANSmITTERS

In the transmitters each button corresponds to a different function, with the sole excep-

tion of the two button transmitters where it is possible to have the same function for 

both buttons (single-channel operation). For double-channel operation which can be 

obtained using the second key, set the two-way DIP-SWITCH, located separately from 

the nine-way user code DIP-SWITCH on the printed circuit board. Once the transmitter's 

functions have been programmed and recognized, make sure that the jumper position 

in the radioprogrammer corresponds to the desired function.

PROGRAmmING THE USER CODE

The transmitters and receivers are supplied with a block of DIP-SW0- with 

which to program the digital codes for each system. Programming can be carried out 

more than once, even after the installation, thus ensuring the total secrecy of the user 

code. To ensure an exact match between the transmitter and receiver codes, when 

programming the various functions must be taken into account.

Functions 

The desired functions in the receiver are selected by setting the jumper situated on 

the circuit board. The functions are printed on the circuit board in silk-screen form 

A, B, C, D.

TECHNICAL SPECIFICATIONS

RECEPTION FREQUENCY

Attention:  The  transmission  frequency  of  these  products  varies  according 

to  the  approved  frequency  and  eventual  personalisation  in  the  country  of 

destination

Country 

Frequency  

Antenna

Italy 

29,875 MHz 

ANQ730

 Europe  

27,195 MHz 

ANQ727

USA 

27,195 MHz 

ANQ727

RECEIVER

- local oscillation frequency tolerance .............................................30p.p.m. (-10°… +55°)

- intermediate frequency ........................................................................................455 kHz

- impedance in input ....................................................................................................50

- sensibility .................................................................................................................0.5µV

- local oscillation emission .................................................................. <-70dBm (<100pW)

- power supply ........................................................................................ 230 Vac 50-60Hz

- operating temperature range ........................................................................-20°...+60°C

TRANSmITTERS

- carrier frequency tolerance .................................................30p.p.m. from -10° to +55°C

- band width ............................................................................................... 10 kHz/ ± 5kHz

- apparent radiated power ........................................................ -10…-7dBm (100-200µW)

- apparent power harmonic products ..................................................... <-64dBm (<1nW)

- power output adjacent channel (± 10 kHz) ........................................ <-37dBm (<0.2µW)

- modulation .......................................................................................................... AM/ASK

- signal modulation.....................................................................................PCM, 1.3ms/bit

- power supply ..................................................................................................12V ± 10%

- maximum power consumption ............................................................................. <38mA

- operating temperature range .......................................................................- 20… +70°C

- relative humidity ......................................................................................................<95%

REmARkS

These instructions are aimed at professionally qualified "INSTALLERS OF 

ELECTRICAL  EQUIPMENT"  in  conformity  with  the  local  standards  and 

regulations in force. 

This appliance must be used exclusively for the purpose for which it has been 

made. Any non authorised modifications are to be considered improper and 

therefore dangerous. 

The manufacturer accepts no liability for damage caused by, or situations 

arising from, the improper use of these appliances.

Description

The 

S46 radioprogramming system consists of one or more transmitter and 

one or more receivers which can be combined to meet the specific needs 

of the client.

The  single  channel  radio  receiver  (with  functions  A,  B,  C,  D)  offers  up  to 

19683 code combinations per appliance set by a block of 9 three-way dip-

switches.

Use

The radioprogrammer allows the remote activation of a single-phase motor 

230V  ac  350W,  with  dynamic  functioning  for  the  sequence  open-stop-

close.

Compatibility with RXPR:

• The transmitters are fitted with a jumper "JC" to maintain compat

-

ibility with receivers of the series non "C".

- Jumper inserted: 

compatible with NON series "C" receivers

- Jumper not inserted:  compatible with series "C" receivers

Transmitter versions
TRQ466200
 

Pocket size transmitters  

2 channels

TRQ466400 

Pocket size transmitters   

4 channels

Receiver versions
RPQ046
  

Radioprogrammer 

 

   

Receiver antenna installation

Minimum and maximum range of the radio controls.

"Range" is intended to mean the working distance, measured in free space, 

between  the  receiver  and  the  transmitter  with  the  antenna  installed.  The 

range is therefore closely linked to the technical characteristics of the system 

(power and sensibility) and varies  according to the characteristics of the site 

in which the system is located. 

It  therefore  follows  that  to  obtain  the  best  results  from  the  radio  control 

the  installation  sites  for  the  receiver  and  the  antenna  should  be  carefully 

chosen.

It is not possible to install 2 receivers at a distance of less than 

1,5m from 

each other. It is good practise to position the receiver away from computer 

systems, alarm systems and other possible sources of disturbance. 

(

A bad choice of positioning could compromise the performance of the 

receiver).

ANTENNA

The installation of the antenna is fundamental, connected to the receiver it 

represents the reception point for the radio control.

When installing the antenna the following points should be observed:

-  Only use a tuned antenna connected to the receiver using a coaxial cable 

RG58 (impedance 50

) with a maximum length of 

15m.

-  The  antenna  should  be  positioned  out  of  doors  in  the  highest  possible 

point, visible and away from metal structures.

N.B. If for some particular reason it is not possible to fit an antenna, a rea-

sonable performance can be obtained by connecting a 

2,5m piece of single 

pole conductor wire (

Ø1mm) to the receiver.

INSTALLATION

Depending on the type of installation, work out the position in which the 

programmer will be situated remembering that the site must be:

- a position safe from accidental collision;

- high enough above the ground to be safe from pools of water;

- in a position which the technician can easily reach.

The  fixing  of  the  case  type  receiver  is  carried  out  by  using  "fast-fitting" 

brackets. The bracket should be fixed to the wall using two raw plugs (check 

that it is plumb to the wall), the case can then be slid onto the bracket and 

fastened securely to the wall. 

The  slot-in  circuit  located  towards  the  bottom  of  the  case  can  be  easily 

extracted to facilitate wiring up the device. 

If any repair work is necessary the case can be easily extracted by pushing 

upwards the action of which will separate it from the bracket.

The 

S46 series conforms to the essential requirements of the directive 99/05/CE and the 

technical reference standards have been applied. This product has been tried and tested 

in the manufacturer's laboratory, during the installation of the product follow the supplied 

indications carefully. 

MODEL

DATE

SERIAL NUMBER

SERIES

Summary of Contents for S46 Series

Page 1: ...to servendosi della staffa fissaggio rapido La staffa viene fissata alla parete con due tasselli curare la messa in bolla Eseguiti i collegamenti elettrici il contenitore viene inserito a scatto sulla stessa staffa In caso di manutenzione è sufficiente una pressione operata sulla scatola dal basso verso l alto per ottenere lo sganciamento del contenitore Collegamento elettrico fig 3 Prima di esegu...

Page 2: ...ive humidity 95 Remarks These instructions are aimed at professionally qualified INSTALLERS OF ELECTRICAL EQUIPMENT in conformity with the local standards and regulations in force This appliance must be used exclusively for the purpose for which it has been made Any non authorised modifications are to be considered improper and therefore dangerous The manufacturer accepts no liability for damage c...

Page 3: ...sorbée 38mA température de fonctionnement 20 70 C humidité relative 95 Remarque Ce livret est destiné à des personnes titulaires d un certificat d aptitude pro fessionnelle pour l installation des APPAREILS ÉLECTRIQUES et requiert une bonne connaissance de la technique appliquée professionnellement L emploietl installationdecetappareildoiventêtreconformesauxinstructions fournies par le Fabricant e...

Page 4: ...zuhaken Elektrischer Anschluss Abb 3 Vor dem Ausführen des elektrischen Anschlusses kontrollieren ob die auf dem Geräteschild angegebene Stromspannung und frequenz mit der der Strom versorgung übereinstimmt ein zweipoliger Schalter dem Gerät vorgeschaltet ist der in offener Stellung mindestens 3 mm Abstand zwischen den Kontakten ermöglicht die Kabel der 230V Leiter durch die Öffnungen A getrennt v...

Page 5: ...n 38 mA temperatura de funcionamiento 20 70 C humedad relativa 95 Advertencias Este manual se dirige a personas habilitadas para la instalación de APARATOS UTILIZADORES DE ENERGÍA ELÉCTRICA y exige el buen conocimiento de la técnica realizada profesionalmente El uso y la instalación de estos aparatos debe cumplir rigurosamente con las indicacio nes facilitadas por el fabricante y las normas de seg...

Page 6: ...eitsvorrichtunge Leyenda A Entrada cables de conexión a alta tensión 230V B Entrada cables de conexión a baja tensión 12 24V antena C Tabique de separación alta baja tensión D Tapones PW Piloto receptor alimentado STS Led di stato TL Trimmer de regulación tiempo de funcionamiento TD Tecla dinámica FTCI Entrada contacto N C para dispositivos de seguridad COLLEGAMENTO ELETTRICO RADIOPROGRAMMATORE RA...

Reviews: