9.0 - Troubleshooting
50
5.
Follow instructions on pages
47 thru 48 to verity the SharpShooter setup parameters.
6.
Power up the Rate Controller. Verify the setup parameters.
7.
Do a “Like Component Swap” to see if the failure follows the component.
8.
Perform dry and wet tests, see 9.2 - SYSTEM TESTING AND TUNING.
9.
If necessary contact your “OEM Dealer Service” so the Capstan diagnostic tools can be used to conduct the SSRS
Display Data Logging Procedure on page 47.
c.
Check for incorrect or damaged tips. The SR110 tips should be on the front row of solenoids. The MR110 tips
should be on the rear or Boosted solenoids. There may be situations when an SR110-06 replaces the SR110-10
tips and a MR110-125 tips replaces the MR110-10. See Tip Selection and Capacities on page
43
.
d.
Using the Pressure Breakout Harness, check the input voltage (12V) and the output signal (2.5V), when the
SharpShooter is in the Manual Mode and adjusted to attain a boom pressure of 50 PSI (2.5V).