9.0 - Troubleshooting
48
9.1.2- SharpShooter with Rate Sync (SSRS Display) Programming
Required Items:
•
Capstan Can Commander.
•
Translator Box and USB Cable.
•
Programming Cable.
[Figure 49]
- Connect the programming cable to the
SSRS Display
①
auxiliary port and to Can 1 port of
②
translator.
Programming
:
1.
Power up the SSRS Display
2.
Plug in Translator and Programming Cable
3.
[Figure 50]
- *Open Capstan Can Commander
- Choose ‘Software Upload’ tab
- Select ‘SSQ/Cab Box (SSRS Display)
- Click ‘Locate Network Devices’ (hardware info
appears)
- Select ‘Erase All Sectors’
- Click Browse and choose code to upload
- Click hardware info above, it will be highlighted in
blue
- Click ‘Begin Upload’ progress bar will appear (wait
for ‘programming complete’)
- Disconnect programming cable
- Power Up the SSRS Display
Figure 49: SSRS Display Programming
Figure 50: Capstan Can Commander
This should be performed only by a
qualified service technician.
1
2