Continuous ventilation after cutting off the hob:
This is not a failure, the fan continuous to protect the electronic device.
The fan cooling stops automatically.
The automatic cooking system doesn‟t start-up:
The cooking zone is still hot [ H ].
The highest power level is set [ 9 ].
The control panel displays [ L ]:
Refer to the chapter control panel locking page.
The control panel displays [ U ]:
Refer to the chapter “Keep warm“.
The control panel displays [ II ]:
Refer to the chapter “Pause“.
The control panel displays [ ] or [ Er03 ] :
An object or liquid covers the touch control keys. The symbol will disappear as soon as
the key is released or cleaned.
The control panel displays [ E2 ] :
The hob has overheated, let it cool and then turn it on again.
The control panel displays [ E3 ] or [ E7 ] :
The pan is not adapted, change the pan.
The control panel displays [ E6 ] :
Defective network. Control the frequency and voltage of the electrical network.
The control panel displays [ E8 ] :
The air inlet of the ventilator is obstructed, release it.
The control panel displays [ E C ] :
Configuration error. Set the table again, referring to the chapter "The [E 4] appears."
If one of the symbols above persists, call the Caple Service.