background image

   

 

 

 

 

 

 

CAREFULLY READ THROUGH THESE INSTRUCTIONS BEFORE INSTALLATION AND USE OF ALL TAP WARE AND WALL 
VALVES 

INSTALLATION and WARRANTY INSTRUCTIONS 

TECHNICAL INFORMATION 

All  flexible  hoses  are  designed  and  manufactured  for  use  with  water  in  exposed  locations only. Do  not  expose  to 
household cleaners, chlorine, chloride, hydrochloric acid or other corrosive chemicals. 

All  connections  with  threads  M10x1  male  must  be  hand  tighten.  Do  not  over  tighten.  Over  tightening  may  cause 
damage to the hose. 

All tap ware washers and o-rings are designed and manufactured for use with water. Do not  expose to household 
cleaners, chlorine, chloride, hydrochloric acid or other corrosive chemicals. 

 

Our tap ware is designed for use with the temperatures and pressures listed below: 

 

minimum cold water supply 10 °C 

 

maximum hot water supply 62 °C 

 

minimum pressure 100 kPa 

 

maximum pressure 500 kPa 

 

maximum fixing torque value = 13.6 Nm 

 

Please note: The recommended pressure for best performance is between 270 kPa and 420 kPa. More pressure than 
420 kPa or less pressure than 270 kPa  may affect the diverting action in side spray tap ware. 

Do not use any Nicolazzi tap ware with sulphurous water. 

The minimum temperature for all tap ware is 10 degrees Celsius . Below 10 degrees Celsius will void the warranty. 

When available, filter systems must be placed between hot and cold supply lines and the tap ware. Improper use or 
non-use of filters may make diverting tap ware with hand sprays perform poorly. 

Don't modify the tap ware and their components. 

Use  only  original  spare  parts  if  there  are  replacements  to  be  ordered.  Installation  must  be  made  by  authorized 
plumbers  or  installers.  Improper  installation  or  diagnosis  of  problems  is  not  covered  by  the  warranty.  Yearly 
maintenance of cleaning and flushing is recommended. 

Operation and use  of any tap ware or wall valve  that  do not conform to these technical instructions will void the 
warranty. 

 

 

 

 

Important Notice     Model : Z3314--44 

Further information Phone (03) 9761 4603                               [email protected] 

Summary of Contents for ARENA Z3314-44

Page 1: ...at Nicolazzi Factory Lead Free Brass Compliant to AZ NZS 3718 Suitable even and uneven pressure Handles are interchangeable Specifications WM22315 AS NZS3662 Canterbury Sink Tap Co Max Min Operating P...

Page 2: ...Please note The recommended pressure for best performance is between 270 kPa and 420 kPa More pressure than 420 kPa or less pressure than 270 kPa may affect the diverting action in side spray tap ware...

Page 3: ...hole sizes Maximum 33mm diameter Under side clearance Maximum 40mm 3 Preparation Tap body Tap body cut out hole sizes Maximum 33mm diameter Under side clearance Maximum 60mm Continue Tap section Flus...

Page 4: ...r plate 6 onto the tap side body until it is flush with the counter top surface Thread the retaining flange and handle 7 onto the cartridge securing it firmly by hand only See the Removing and replaci...

Page 5: ...he escutcheon thread extension followed by the brass lock nut 17 Secure on to the worktop underside but do not over tighten 5 Thread the bottom brass lock nut 9 followed by the bottom rubber washer 10...

Page 6: ...ly DO NOT over tighten 19 Install the supplied mounting stud 20 into tap the body spout and verify that they are securely installed 6 Continue Feed the O ring 21 over the water supply hose Note Insert...

Page 7: ...o the stud Then screw the mounting nut 24 onto the stud Screw the mounting stud until the half ring rubber gasket mates up with the underside of the sink Check the position on the spout body then tigh...

Page 8: ...any water leaks Installation Instructions Model Z3314 44 Further information Phone 03 9761 4603 sales sinkandtap com au Connect the Diverter Hot and Cold water supply flexi hoses 25 and 26 to the prot...

Page 9: ...se 33 through from the bottom end of the hand spray escutcheon Connect the flexi hose to the curved joint holder ensuring that the O ring 32 is placed on the male end of the flexi hose Insert Check va...

Page 10: ...603 sales sinkandtap com au 10 Before use Turn on the Hot and Cold supplies to the tap Maximum temperature for Hot water supply to the tapware is 62 C Minimum recommended pressure is 100 kPa Maximum r...

Page 11: ...Spare Parts list Model Z3314 44 Further information Phone 03 9761 4603 sales sinkandtap com au 11...

Page 12: ...Spare Parts list Model Z3314 44 Further information Phone 03 9761 4603 sales sinkandtap com au 12...

Page 13: ...To reassemble reverse the disassembly procedure given above The retaining flange only needs to be hand tight NOTE DO NOT USE A SHIFTER TIGHTEN BY HAND ONLY Do not over tighten as this could damage th...

Page 14: ...not replace the diverter Service or replace the hand spray if there is a continous leak Turn off the hot and cold supply lines to the tap set Not shown Remove the handle and retaining flange Refer to...

Page 15: ...ot change the cartridge Unscrew and clean the aerator 1 Unscrew and clean the filters inside the supply connections 3 Check the supply lines for kinks or obstructions 2 3 and 4 Ensure that the Check v...

Page 16: ...juice this will lighten the dark colouring Shiny Brass Polished Nickel has an ageing process and will tarnish over time Tuscan Brass is a living finish and also carries NO warranty It will lighten wit...