background image

 

Version 4.1, 13

th 

Aug. 2021, Page 

1

 of 

7

 

GalvinSafe

®

 Pedestal Floor Mtd, Axion

®

 MSR Eye/Face 

Wash Head, S/S Bowl, Hand & Foot Act, (HAWS) 

PRODUCT CODE:  

Galvin Engineering: 190.82.11.90  

HAWS: 7777-A + SP220SS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRE - INSTALLATION 

LOCATION OF UNIT: 

The Model 190.82.11.90 (7777-A) Stainless Steel combination 

Shower Eye/Face Wash should be installed in close proximity to potential accident 
areas. It should be clearly identified, free from obstructions and easy to access. 

 

SUPPLY LINE: 

The minimum recommended line size is 

1/2” BSPT with 210 – 600 kPa 

flowing pressure. Where sediment or mineral content is a problem, an inlet filter is 
recommended. 

 

PLUMBING CONNECTIONS: 

Inlet supply is female 1/2

” BSPT. Waste outlet is male 1-

1/4

” BSPT. 

 

Summary of Contents for GalvinSafe 190.82.11.90

Page 1: ...777 A Stainless Steel combination Shower Eye Face Wash should be installed in close proximity to potential accident areas It should be clearly identified free from obstructions and easy to access SUPPLY LINE The minimum recommended line size is 1 2 BSPT with 210 600 kPa flowing pressure Where sediment or mineral content is a problem an inlet filter is recommended PLUMBING CONNECTIONS Inlet supply ...

Page 2: ...91 12 32 EMERGENCY EYE SAFETY SIGN 3 190 92 41 30 VALVE ASSEMBLY 4 190 91 22 12 FOOT TREADLE 5 190 92 12 10 EYE FACE WASH ASSEMBLY 6 190 91 80 33 TEST TAG 7 L STRAINER 8 SS DUST COVER ASSEMBLY OPTIONAL spare parts will require special order or may not be available contact Galvin engineering for more details ...

Page 3: ...Version 4 1 13th Aug 2021 Page 3 of 7 ...

Page 4: ...Version 4 1 13th Aug 2021 Page 4 of 7 ...

Page 5: ...uate line flushing Unscrew eye face wash head and remove the four screws to disassemble head Clean flow control and reassemble Head c Remove plug located on L Strainer using a 9 16 wrench to access clean filter screen 3 Eye face wash streams do not meet desired eye level 3 Possible blocked flow control see above solution Possible non leveled eye face wash assembly 4 Water does not drain properly 4...

Page 6: ...Version 4 1 13th Aug 2021 Page 6 of 7 ...

Page 7: ...urer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long as the terms of the Manufacturer s warranty are complied with The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty and Galvin Engineering Pty Ltd shall not ...

Reviews: