6
-12
4
[Object
S
ize (%)] [Change Ratio (%)] [Duration (
S
ec)]
Set the lower limit for the size, change ratio, and
judgment time for the set detection area to trigger
detection. If the value set here is exceeded, “Detected”
mode is triggered.
Click the text box to enter a value directly, or specify a
value using the slider.
For details on the setting method, see “Setting Detection
Criteria per Detection Type” (P. 6-13).
Setting Event Operations ([Event] tab)
Set operations to be performed upon detection of
changes in a subject.
[Event] tab
1
S
pecify the operation timing. (Multiple checkboxes can
be selected.)
[ON Event Operation] checkbox
When selected, the operations set in
2
Notification] and [Upload] are performed the moment
detected mode is triggered to ON.
[OFF Event Operation] checkbox
When selected, the operations set in
2
Notification] and [Upload] are performed the moment
detected mode is triggered to OFF.
[Detected mode Operation] checkbox
When selected, the operations set in
2
Notification] and [Upload] are performed for as long as
detected mode is active.
2
S
pecify the event operation. (Multiple checkboxes can
be selected.)
[E-mail Notification] checkbox
When selected, e-mail notification is performed at the
timing set in
1
. [E-mail Notification] must be set in
advance under [Upload] in the Setting page (P. 5-16).
[Upload] checkbox
When selected, upload is performed at the timing set in
1
. General upload must be set in advance under
[Upload] in the Setting page (P. 5-14).
3
S
pecify the audio playback timing.
[Audio Playback at ON Event] checkbox
When selected, the sound set in
4
[Sound Clip Name]
is played at the moment the detected mode is
triggered to ON.
[Audio Playback at OFF Event] checkbox
When selected, the sound set in
4
[Sound Clip Name]
is played at the moment the detected mode is turned
OFF.
4
S
et the playback sound.
[
S
ound Clip Name]
Select the sound that is to be played. The sound clip
name set for [Sound Clip Upload] under [Event] in the
Setting page is shown in the pull-down list (P. 5-21).
[Volume]
Set the audio playback volume in the range of 1 to 100.
Setting Detection Areas
Set detection areas in the image display area.
S
etting a [Rectangular] detection area
By default, a rectangle is shown in the image display area.
Move or resize that rectangle to set a detection area.
Important
• It is recommended that the detection criteria are set in a
condition as close as possible to the condition in which the
camera is actually used.