5
-17
5
S
ett
ing Page
Image Server
1
[Maximum Number of Clients]
Set the maximum number of clients that can be
connected to the camera at the same time. Up to 30
clients can be set.
If 0 is set, connection is prohibited except for the
Administrator.
2
[Camera Control Queue Length]
Set the maximum queue length for clients requesting
camera control privilege from the viewer. The maximum
number is 30. Enter an integer from 0 to 30. If 0 is set,
camera control is prohibited except for the
Administrator.
3
[Maximum Connection Time (sec.)]
Set the time in seconds during which an individual
client can connect to the camera. The maximum
number is 65535. Enter an integer from 0 to 65535. If 0
is set, the connection time becomes unlimited.
4
[Camera Control Time (sec.)]
Set the maximum time during which the viewer can
control the camera. The maximum number is 3600.
Enter an integer from 1 to 3600.
Audio Server
1
[Audio Transmission from the Camera]
When [Enable] is selected, the audio input through the
microphone attached to the camera can be transmitted
to the VB-M700/600 Viewer.
2
[Input Volume]
Set the volume of input for the microphone connected
to the camera in the range of 1 to 100. The greater the
value, the larger the input volume becomes.
3
[Voice Activity Detection]
If [Enable] is selected, the audio transmission is
stopped temporarily when no audio is output. This way,
the load of the applicable network can be reduced.
4
[Audio Reception from Viewer]
If [Enable] is selected, the audio received from the
bundled RM-Lite Viewer can be output from the
speaker with amplifier connected to the camera.
5
[Output Volume]
Set the volume of output for the speaker connected to
the camera in the range of 1 to 100. The greater the
value, the larger the output volume becomes.
6
[Echo Canceller]
If [Enable] is selected, echo between the microphone
and speaker is suppressed.
7
[Audio Input]
Set the microphone input. Select [Line In], [Microphone
In (dynamic microphone)] or[Microphone In
(condenser microphone)].
[Server]
Setting the Image Server, Audio Server and HTTP Server
The following can be set here.
• Image
S
erver
Set the image transmission from the camera.
• Audio
S
erver
Set the audio transmission/reception.
• HTTP
S
erver
Set the authentication method, HTTP port and
web page delivery.
• Audio Transmission
• Input Volume
• Voice Activity Detection
• Echo Canceller
• Audio Reception
• Output Volume
Summary of Contents for VB-M700F
Page 12: ...xii...
Page 24: ...1 12...
Page 40: ...3 10...
Page 77: ...Chapter 6 Admin Tools Privacy Mask Setting Intelligent Function Setting Viewing Logs...
Page 94: ...6 18...
Page 110: ...7 16...