e
Commands
POWER
Mode
Control Setting
Referenc
Function
This controls the power supply.
Parameter
ID
Parameter Meaning
ON
Power ON
OFF
Power OFF
The RANGE command can be used to obtain the parameters that can be set at that time.
Response
An “i:OK” is returned after setting is successful.
Description
This performs ON/OFF control of the power supply.
(1)
This command is identical to pressing the POWER button on the remote control or main unit.
(2)
After sending this command, use GET POWER to obtain the power supply state at regular
intervals, and check that it is in the controlled state (off or on).
(3)
The table below shows the POWER command responses according to the power supply state.
POWER Command Responses by Power Supply State
Command
POWER ON
POWER OFF
Status
Off
○
○
Off→lit
○
○
Lamp on
○
○
Lit→off
△
○
Lit→standby
○
○
Standby
○
○
○:
i:OK
Standby→lit
○
○
△:
i:BUSY
(4) The current mode can be viewed with the GET command.
Example
Control
>
POWER ON
<
i:OK
Reference
> GET POWER or ?POWER
< g:POWER=OFF
Obtain settable parameters
> RANGE POWER
< r:POWER=I,ON,OFF
*Commands are indicated by “>”, and responses are indicated by “<”.
Supported Command States
Parameter
Power supply
Input
Mode
OFF
ON
PM
D-RGB
A-RGB1 A-RGB2
Comp
Video
S-Video
None
Remote
Local
ON
○
○
○
○
○
○
○
○
○
○
○
×
OFF
○
○
○
○
○
○
○
○
○
○
○
×
※
When the power supply state is in the process of switching, an “i:BUSY” reply may be sent.