Chapter 6
6-2
6.2 Service Error Code
6.2.1 Service Error Code
0025-3174
T-6-2
No. T/R
Description
##100
[T]
at time of transmission, the procedural signal has been transmitted more than specified.
##101
[T/R]
the modem speed does not match that of the other party.
##102
[T]
at time of transmission, fall-back cannot be used.
##103
[R]
at time of reception, EOL cannot be detected for 5 sec (15 sec if CBT).
##104
[T]
at time of transmission, RTN or PIN is received.
##106
[R]
at time of reception, the procedural signal is received for 6 sec while in wait for the signal.
##107
[R]
at time of reception, the transmitting party cannot use fall-back.
##109
[T]
at time of transmission, a signal other than DIS, DTC, FTT, CFR, or CRP is received, and the procedural signal has been sent more than
specified.
##111
[T/R]
memory error has occurred.
##114
[R]
at time of reception, RTN is transmitted.
##200
[R]
at time of reception, no image carrier is detected for 5 sec.
##201
[T/R]
DCN is received outside the normal parity procedure.
##204
[T]
DTC without transmission data is received.
##220
[T/R]
system error (main program out of control) has occurred.
##223
[T/R]
while a communication is under way, the line is cut.
##224
[T/R]
in G3 communication, an error has occurred in the procedural signal.
##226
[T/R]
the stack printer has fallen outside the RAM area.
##229
[R]
the recording unit has remained locked for 1 min.
##232
[T]
encoding error has occurred.
##237
[R]
decoding error has occurred.
##238
[R]
the print control unit is out of order.
##261
[T/R]
system error has occurred.
##280
[T]
at time of transmission, the procedural signal has been transmitted more than specified.
##281
[T]
at time of transmission, the procedural signal has been transmitted more than specified.
##282
[T]
at time of transmission, the procedural signal has been transmitted more than specified.
##283
[T]
at time of transmission, the procedural signal has been transmitted more than specified.
##284
[T]
at time of transmission, DCN is received after transmission of TCF.
##285
[T]
at time of transmission, DCN is received after transmission of EOP.
##286
[T]
at time of transmission, DCN is received after transmission of EOM.
##287
[T]
at time of transmission DCN is received after transmission of MPS.
##288
[T]
after transmission of EOP, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##289
[T]
after transmission of EOM, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##290
[T]
after transmission of MPS, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##670
[T]
at time of V.8 late start, the V.8 ability of DIS front the receiving party is expected to be detected, and the CI signal is expected to be
transmitted in response; however, the procedure fails to advance, and the line is released because of T1 time-out.
##671
[R]
at time of V.8 arrival, procedure fails to move to phase 2 after detection of CM signal from caller, causing T1 time-out and releasing line.
##672
[T]
at time of V.34 transmission, a shift in procedure from phase 2 to phase 3 and thereafter stops, causing the machine to release the line and
suffer T1 timeout.
##673
[R]
at time of V.34 reception, a shift in procedure from phase 2 to phase 3 and thereafter stops, causing the machine to release the line and suffer
T1 timeout.
##674
[T]
at time of V.34 transmission, a shift in procedure from phase 3 and phase 4 to the control channel and thereafter stops, causing the machine
to release the line and suffer T1 timeout.
##675
[R]
at time of V.34 reception, a shift in procedure from phase 3 and phase 4 to the control channel and thereafter stops, causing the machine to
release the line and suffer T1 timeout.
##750
[T]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-NULL, causing the procedural signal to be
transmitted more than specified.
##752
[T]
at time of ECM transmission, DCN is received after transmission of PPS-NULL.
##753
[T]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-NULL, or T5 time-
out (60 sec) has occurred.
##754
[T]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-NULL.
##755
[T]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-MPS, causing the procedural signal to be transmitted
more than specified.
##757
[T]
at time of ECM transmission, DCN is received after retransmission of PPS-MPS.
##758
[T]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS, or T5 time-out
(60 sec) has occurred.
##759
[T]
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS.
##760
[T]
at time of ECM transmission, no meaningful signal is received after transmission of PPS-EOM, causing the procedural signal to be
transmitted more than specified.
Summary of Contents for Super G3 Fax Board-AF1
Page 1: ...Jul 20 2010 Service Manual FAX Board Super G3 Fax Board AF1 ...
Page 2: ......
Page 6: ......
Page 10: ...Contents ...
Page 11: ...Chapter 1 Specifications ...
Page 12: ......
Page 13: ...Contents Contents 1 1 Product Specifications 1 1 1 1 1 Product Specifications 1 1 ...
Page 14: ......
Page 16: ......
Page 17: ...Chapter 2 Installation ...
Page 18: ......
Page 20: ......
Page 27: ...Chapter 3 Functions ...
Page 28: ......
Page 29: ...Contents Contents 3 1 Basic Construction 3 1 3 1 1 Overview 3 1 ...
Page 30: ......
Page 33: ...Chapter 4 Parts Replacement Procedure ...
Page 34: ......
Page 36: ......
Page 38: ......
Page 39: ...Chapter 5 Service Mode ...
Page 40: ......
Page 64: ......
Page 65: ...Chapter 6 Error Code ...
Page 66: ......
Page 68: ......
Page 72: ......
Page 73: ...Jul 20 2010 ...
Page 74: ......