3-34
CHAPTER 3. REPAIR INSTRUCTION
4
When the message on the right appears, go to 5.
5
1. Remove the ND Filter.
2. Attach the two W-10 Filters.
Place the camera so that the lens is set against
the center part of the Color Viewer.
3. Click the “ADJUST” button.
Power
Source
Stand
Color Viewer
Personal
Computer
CAMERA
BODY
W-10
Filter
Power
Source
Stand
Color Viewer
Personal
Computer
CAMERA
BODY
C-12
Filter
6
When the message on the right appears, go to 7.
7
1. Remove the two W-10 Filters.
2. Attach the C-12 Filter.
Place the camera so that the lens is set against
the center part of the Color Viewer.
3. Click the “ADJUST” button.