3-1
CHAPTER 3. REPAIR INSTRUCTION
Fig. 3-1 Precaution on flash high tension circuit
1. Before Starting the Repair Work
Be sure to read the following precaution before starting the repair work.
1.1 Precaution on Flash High Tension Circuit
•
When the FRONT COVER UNIT and REAR COVER UNIT are removed, be sure to discharge the main
capacitor.
(Discharging resistor : 1 k
Ω
, approx. 5 W.)
•
First contact the GND
terminal of the main capacitor with the discharging resistor. Then contact the
positive
terminal of the main capacitor.
CAUTION:
Be careful of electric shock because the circuit is the high tension circuit.
1.2 List of Tools
The following tools are used for the re-assembling during service.
(1) List of tools
New
Name of tools
Part No.
Remarks
Screwdriver (Local Purchase)
Tweezers (Local Purchase)
Soldering iron (Local Purchase)
1.3 List of Supplies
The following supplies are used for the re-assembling during service.
(1) List of supplies
New
Name of supplies
Part No.
Remarks
ADHESIVE TAPE SONY T4000
CY4-6012-000
Double-sided Tape
ADHESIVE TAPE 3M No.56
CY4-6018-000
Insulation Tape
DIA BOND No.1663G
CY9-8129-000
Solder (Local Purchase)
FLASH UNIT
(1k /5W)
+ terminal
– terminal
Summary of Contents for PowerShot A100
Page 1: ......
Page 4: ......
Page 6: ......
Page 40: ......
Page 42: ......
Page 50: ......
Page 52: ......
Page 94: ...3 42 CHAPTER 3 REPAIR INSTRUCTION 4 Make sure to appear err 0 on the bottom line ...
Page 96: ......
Page 109: ......
Page 111: ......
Page 122: ...C CANON INC 2002 01 June 2002 3 3 OPR PCB ASS Y ...
Page 123: ...C CANON INC 2002 01 June 2002 3 4 RLS PCB ASS Y ...
Page 124: ...C CANON INC 2002 01 June 2002 3 5 BL FPC ASS Y ...
Page 126: ...PowerShot A100 A200 AF Chart ...
Page 127: ......
Page 128: ...PowerShot A100 A200 AF Chart ...
Page 129: ...Dimensions 467 83mm 370 89mm 96 94mm 346 98mm 260 0mm 93 00mm ...