3-16
CHAPTER 3. REPAIR INSTRUCTION
Fig. 3-16 CCD ASS’Y
2.14 CCD ASS’Y
(1) CCD UNIT, CCD RUBBER, IR FILTER
1. Remove the three screws
d
.
2. Remove the CCD UNIT.
NOTE (Assembling)
Align the two positioning dowels of the OPTICAL UNIT at each location.
3. Remove the CCD RUBBER.
4. Remove the IR FILTER.
OPTICAL UNIT
IR FILTER
CCD RUBBER
CCD UNIT
(1)-1
(1)-2
(1)-3
(1)-4
Positioning when assembling
d
XA4-9140-307
METAL
M1.4
(SELF TAP)
3.0mm
NOTE (Assembling)
d