2-6
CHAPTER 2. TECHNICAL DESCRIPTION
Error Code
E27
E30
E50
E51
E52
Name
CF WRITE
TIME OVER
POWER OFF
ERROR
CF FORMAT
ERROR
CF ACCESS
ERROR
QUICK REVIEW
ERROR
Occurrence Conditions
Free area could not be secured in the
buffer for the photograph image within
the specified time in the continuous
shooting mode.
The camera power was turned OFF while
the image was being recorded to the CF
Card. (The error code is displayed when
the camera is next turned ON.)
*
This error may occur after E23.
The CF Card could not be formatted
properly.
When image data cannot be read from
CF normally.
Review of the photograph image failed.
Cause and Probable Faulty Part
CF CARD
MAIN PCB ASS’Y
The battery or DC plug was removed
while the image was being recorded to
the CF Card.
→
Remedy: Restart the camera.
CF CARD
CF CARD
MAIN PCB ASS’Y
Summary of Contents for PowerShot A100
Page 1: ......
Page 4: ......
Page 6: ......
Page 40: ......
Page 42: ......
Page 50: ......
Page 52: ......
Page 94: ...3 42 CHAPTER 3 REPAIR INSTRUCTION 4 Make sure to appear err 0 on the bottom line ...
Page 96: ......
Page 109: ......
Page 111: ......
Page 122: ...C CANON INC 2002 01 June 2002 3 3 OPR PCB ASS Y ...
Page 123: ...C CANON INC 2002 01 June 2002 3 4 RLS PCB ASS Y ...
Page 124: ...C CANON INC 2002 01 June 2002 3 5 BL FPC ASS Y ...
Page 126: ...PowerShot A100 A200 AF Chart ...
Page 127: ......
Page 128: ...PowerShot A100 A200 AF Chart ...
Page 129: ...Dimensions 467 83mm 370 89mm 96 94mm 346 98mm 260 0mm 93 00mm ...