machine.
##671
RX
In V.8 call reception, the procedure fails to proceed to phase 2
after CM detection, causing T1 time-over.
- In bit 0 of the service data #1
SSSW SW28, prohibit the V.8 /
V.34 procedure of the sending
machine.
##672
TX
In V.34 transmission, the procedure fails to proceed from phase
2 to phase 3 or later, causing T1 time-over
- In bit 0 of the service data #1
SSSW SW28, prohibit the V.8 /
V.34 procedure of the sending
machine.
##673
RX
In V.34 reception, the procedure fails to proceed from phase 2 to
phase 3 or later, causing T1 time-over
- In bit 0 of the service data #1
SSSW SW28, prohibit the V.8 /
V.34 procedure of the sending
machine.
##674
TX
In V.34 transmission, the procedure fails to proceed from phase
3 or 4 to the control channel or later, causing T1 time-over
- In bit 0 of the service data #1
SSSW SW28, prohibit the V.8 /
V.34 procedure of the sending
machine.
##675
RX
In V.34 reception, the procedure fails to proceed from phase 3 or
4 to the control channel or further, causing T1 time-over
- In bit 0 of the service data #1
SSSW SW28, prohibit the V.8 /
V.34 procedure of the sending
machine.
##750
TX
After transmitting PPS-NULL in ECM transmission, no
significant signal has been received, and re-transmission of the
procedure signal has been attempted the number of specified
times but failed.
- Try a higher transmission level.
##752
TX
After transmitting PPS-NULL in ECM transmission, DCN has
been received.
- Try a higher transmission level.
##753
TX
After transmitting PPS-NULL in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60 sec.)
has occurred.
- Increase the period of time of the
T5 time-over.
##754
TX
After transmitting PPS-NULL in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed.
- Try a higher transmission level.
##755
TX
After transmitting PPS-MPS in ECM transmission, no
significant signal has been received, and re-transmission of the
procedure signal has been attempted the number of specified
times but failed.
- Try a higher transmission level.
##757
TX
After transmitting PPS-MPS in ECM transmission, DCN has
been received.
- Try a higher transmission level.
##758
TX
After transmitting PPS-MPS in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60 sec.)
has occurred.
- Increase the period of time of the
T5 time-over.
##759
TX
After transmitting PPS-MPS in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed.
- Try a higher transmission level.
##760
TX
After transmitting PPS-EOM in ECM transmission, no
significant signal has been received, and re-transmission of the
procedure signal has been attempted the number of specified
times but failed.
- Try a higher transmission level.
##762
TX
After transmitting PPS-EOM in ECM transmission, DCN has
been received.
- Try a higher transmission level.
16 / 63
Summary of Contents for PIXMA MX870 Series
Page 8: ...5 63 ...
Page 9: ...6 63 ...
Page 31: ...8 Remove the main case no screws 28 63 ...
Page 34: ...31 63 ...
Page 35: ...4 Remove the LCD ass y no screws 5 Remove the panel board 11 screws 32 63 ...
Page 39: ...2 Remove the PE sensor board 5 screws 36 63 ...
Page 64: ... 2 Service test print Service test print sample unified inspection pattern print 61 63 ...
Page 65: ... 3 Ink absorber counter value print Print sample 4 6 Verification After Repair 62 63 ...