##763
TX
After transmitting PPS-EOM in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60 sec.)
has occurred.
- Increase the period of time of the
T5 time-over.
##764
TX
After transmitting PPS-EOM in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed.
- Try a higher transmission level.
- Increase the transmission level of
the receiving machine.
##765
TX
After transmitting PPS-EOP in ECM transmission, no
significant signal has been received, and re-transmission of the
procedure signal has been attempted the number of specified
times but failed.
- Try a higher transmission level.
- Increase the transmission level of
the receiving machine.
##767
TX
After transmitting PPS-EOP in ECM transmission, DCN has
been received.
- Try a higher transmission level.
##768
TX
After transmitting PPS-EOP in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60 sec.)
has occurred.
- Increase the period of time of the
T5 time-over.
##769
TX
After transmitting PPS-EOP in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed.
- Try a higher transmission level.
- Increase the transmission level of
the receiving machine.
##770
TX
After transmitting EOR-NULL in ECM transmission, no
significant signal has been received, and re-transmission of the
procedure signal has been attempted the number of specified
times but failed.
- Try a higher transmission level.
- Increase the transmission level of
the receiving machine.
##772
TX
After transmitting EOR-NULL in ECM transmission, DCN has
been received.
- Try a higher transmission level.
##773
TX
After transmitting EOR-NULL in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60 sec.)
has occurred.
- Increase the period of time of the
T5 time-over.
##774
TX
After transmitting EOR-NULL in ECM transmission, ERR has
been received.
- Try a higher transmission level.
##775
TX
After transmitting EOR-MPS in ECM transmission, no
significant signal has been received, and re-transmission of the
procedure signal has been attempted the number of specified
times but failed.
- Try a higher transmission level.
##777
TX
After transmitting EOR-MPS in ECM transmission, DCN has
been received.
- Try a higher transmission level.
##778
TX
After transmitting EOR-MPS in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60 sec.)
has occurred.
- Increase the period of time of the
T5 time-over.
##779
TX
After transmitting EOR-MPS in ECM transmission, ERR has
been received.
- Try a higher transmission level.
##780
TX
After transmitting EOR-EOM in ECM transmission, no
significant signal has been received, and re-transmission of the
procedure signal has been attempted the number of specified
times but failed.
- Increase the transmission level of
the receiving machine.
##782
TX
After transmitting EOR-EOM in ECM transmission, DCN has
been received.
- Increase the transmission level of
the receiving machine.
##783
TX
After transmitting EOR-EOM in ECM transmission, re-
transmission of the procedure signal has been attempted the
number of specified times but failed, or T5 time-over (60 sec.)
- Increase the period of time of the
T5 time-over.
17 / 63
Summary of Contents for PIXMA MX870 Series
Page 8: ...5 63 ...
Page 9: ...6 63 ...
Page 31: ...8 Remove the main case no screws 28 63 ...
Page 34: ...31 63 ...
Page 35: ...4 Remove the LCD ass y no screws 5 Remove the panel board 11 screws 32 63 ...
Page 39: ...2 Remove the PE sensor board 5 screws 36 63 ...
Page 64: ... 2 Service test print Service test print sample unified inspection pattern print 61 63 ...
Page 65: ... 3 Ink absorber counter value print Print sample 4 6 Verification After Repair 62 63 ...